02659
四乙二醇二甲醚
analytical standard
别名:
2,5,8,11,14-五氧杂十五烷, 二甲基四甘醇, 二甲氧基四乙二醇, 双[2-(2-甲氧基乙氧基)乙基]醚, 四甘醇二甲醚
等级
analytical standard
质量水平
蒸汽密度
7.7 (vs air)
蒸汽压
<0.01 mmHg ( 20 °C)
方案
≥99.7% (GC)
自燃温度
510 °F
保质期
limited shelf life, expiry date on the label
range of application measuring range
≤60 °C
折射率
n20/D 1.432 (lit.)
n20/D 1.432
沸点
275-276 °C (lit.)
mp
−30 °C (lit.)
密度
1.009 g/mL at 25 °C (lit.)
应用
environmental
包装形式
neat
SMILES字符串
COCCOCCOCCOCCOC
InChI
1S/C10H22O5/c1-11-3-5-13-7-9-15-10-8-14-6-4-12-2/h3-10H2,1-2H3
InChI key
ZUHZGEOKBKGPSW-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
一般描述
Tetraethylene glycol dimethyl ether is a non-volatile, higher molecular weight glyme solvent.
This compound is listed in the SVHC (Substances of very high concern) candidate list of ECHA (European Chemicals Agency)
应用
Tetraethylene glycol dimethyl ether may be used as an analytical reference standard for the quantification of the analyte in water samples using gas chromatography/mass spectrometry technique.
警示用语:
Danger
危险声明
危险分类
Repr. 1B
补充剂危害
储存分类代码
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
WGK
WGK 1
闪点(°F)
276.8 °F - closed cup
闪点(°C)
136 °C - closed cup
个人防护装备
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
Stability of superoxide radicals in glyme solvents for non-aqueous Li?O 2 battery electrolytes
Schwenke UK
Physical Chemistry Chemical Physics, 15(28), 11830-11839 (2013)
Simultaneous determination of six hydrophilic ethers at trace levels using coconut charcoal adsorbent and gas chromatography/mass spectrometry.
Stepien DK and Puttmann W.
Analytical and Bioanalytical Chemistry, 405(5), 1743-1751 (2013)
Mingchao Shen et al.
Journal of biomaterials science. Polymer edition, 13(4), 367-390 (2002-08-06)
Polyethylene oxide (PEO) surfaces reduce non-specific protein and cell interactions with implanted biomaterials and may improve their biocompatibility. PEO-like polymerized tetraglyme surfaces were made by glow discharge plasma deposition onto fluorinated ethylene propylene copolymer (FEP) substrates and were shown to
Complement activation on poly(ethylene oxide)-like radiofrequency glow discharge-deposited surfaces.
Luisa Mayorga Szott et al.
Journal of biomedical materials research. Part A, 96(1), 150-161 (2010-11-26)
Nonspecific protein adsorption, particularly fibrinogen (Fg), is thought to be an initiating step in the foreign body response (FBR) to biomaterials by promoting phagocyte attachment. In previous studies, we therefore prepared radiofrequency glow discharge (ethylene oxide)-like tetraglyme (CH(3)O(CH(2)CH(2)O)(4)CH(3)) coatings adsorbing
Adam L Sturlaugson et al.
The journal of physical chemistry. B, 114(16), 5350-5358 (2010-04-09)
Optical heterodyne-detected optical Kerr effect (OHD-OKE) experiments and pulsed field-gradient spin-echo NMR (PFGSE-NMR) experiments were performed to measure the rotational and translational diffusion constants of a polyether, tetraethylene glycol dimethyl ether (TEGDE), in binary mixtures with water over concentrations ranging
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持