跳转至内容
Merck
CN

A0156

Sigma-Aldrich

N-(4-氨基丁基)-N-乙基异鲁米诺

≥90%, powder

别名:

4-(N1-乙基-4-氨基丁基氨基)邻苯二甲酰肼, 6-[N-(4-氨基丁基)-N-乙氨基]-2,3-二氢-1,4-邻苯二甲酰肼, ABEI

登录查看公司和协议定价


About This Item

经验公式(希尔记法):
C14H20N4O2
CAS号:
分子量:
276.33
Beilstein:
920895
MDL编号:
UNSPSC代码:
12352204
PubChem化学物质编号:
NACRES:
NA.83

产品名称

N-(4-氨基丁基)-N-乙基异鲁米诺, ≥90%

质量水平

方案

≥90%

表单

powder

mp

259-260 °C (lit.)

溶解性

glacial acetic acid: 50 mg/mL, clear, colorless to yellow

储存温度

2-8°C

SMILES字符串

CCN(CCCCN)c1ccc2C(=O)NNC(=O)c2c1

InChI

1S/C14H20N4O2/c1-2-18(8-4-3-7-15)10-5-6-11-12(9-10)14(20)17-16-13(11)19/h5-6,9H,2-4,7-8,15H2,1H3,(H,16,19)(H,17,20)

InChI key

LEOJISUPFSWNMA-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

相关类别

特点和优势

高效的化学发光 NH2 偶联试剂,用于检测低至皮摩尔范围的各种蛋白质。

其他说明

据报道,在化学发光测定中使用这种材料具有明显优于传统放射免疫测定的优点。

储存分类代码

11 - Combustible Solids

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

Eyeshields, Gloves, type N95 (US)


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Zian Lin et al.
Journal of chromatography. A, 1170(1-2), 118-121 (2007-10-02)
A simple and convenient end-column chemiluminescence (CL) detection coupled to pressurized capillary electrochromatography (pCEC) was described. Luminol and N-(4-aminobutyl)-N-ethylisoluminol (ABEI) were adopted as mode compounds to evaluate the feasibility of end-column reactor. Detailed analysis of ABEI revealed that the high
Dayong Tian et al.
Chemical communications (Cambridge, England), 47(17), 4959-4961 (2011-03-25)
A novel strategy for the synthesis of CF-AuNMs by reducing HAuCl(4) with ABEI in aqueous solution at room temperature is reported. No additional stabilizing and reducing reagents are needed, and various morphologies of CF-AuNMs can be obtained. It could be
M-L Calvo-Muñoz et al.
Bioelectrochemistry (Amsterdam, Netherlands), 66(1-2), 139-143 (2005-04-19)
The electrochemiluminescence (ECL) of a luminol derivate (ABEI) generated both by a carbon electrode and a polypyrrole-coated carbon electrode was examined. It was found that the polypyrrole film (ppy) did not inhibit the ECL. After that, ABEI anchored on a
Ying Chai et al.
Analytica chimica acta, 715, 86-92 (2012-01-17)
An electrochemiluminescence (ECL) biosensor for simultaneous detection of adenosine and thrombin in one sample based on bifunctional aptamer and N-(aminobutyl)-N-(ethylisoluminol) functionalized gold nanoparticles (ABEI-AuNPs) was developed. A streptavidin coated gold nanoparticles modified electrode was utilized to immobilize biotinylated bifunctional aptamer
F Kohen et al.
Steroids, 38(1), 73-88 (1981-07-01)
A solid-phase immunoassay procedure for the determination of progesterone in human plasma is described, which utilizes chemiluminescence as the end-point. A progesterone-isoluminol conjugate serves as the chemiluminescent marker. An IgG fraction of antiserum to progesterone-11 alpha-hemisuccinate bovine serum albumin is

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门