Merck
CN

238376

Sigma-Aldrich

1-氯戊烷

99%

登录查看公司和协议定价

别名:
戊基氯, 氯代正戊烷
线性分子式:
CH3(CH2)4Cl
CAS号:
分子量:
106.59
Beilstein:
1696936
EC 号:
MDL编号:
PubChem化学物质编号:

质量水平

检测方案

99%

形式

liquid

折射率

n20/D 1.412 (lit.)

bp

107-108 °C (lit.)

溶解性

alcohol: miscible(lit.)
diethyl ether: miscible(lit.)
water: insoluble(lit.)

密度

0.882 g/mL at 25 °C (lit.)

SMILES string

CCCCCCl

InChI

1S/C5H11Cl/c1-2-3-4-5-6/h2-5H2,1H3

InChI key

SQCZQTSHSZLZIQ-UHFFFAOYSA-N

正在寻找类似产品? Visit 产品对比指南

一般描述

1-Chloropentane forms asymmetric and symmetric pairs on the surface of Si (100)-2×1. Reaction of living polystyrene with 1-chloropentane (small molecule-polymer reaction) has been studied.

象形图

FlameExclamation mark

警示用语:

Danger

危险分类

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Flam. Liq. 2

储存分类代码

3 - Flammable liquids

WGK

WGK 3

闪点(°F)

53.6 °F - closed cup

闪点(°C)

12 °C - closed cup

个人防护装备

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter

法规信息

危险化学品

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

为方便起见,与您过往购买产品相关的文件已保存在文档库中。

访问文档库

难以找到您所需的产品或批次号码?

在网站页面上,产品编号会附带包装尺寸/数量一起显示(例如:T1503-25G)。请确保 在“产品编号”字段中仅输入产品编号 (示例: T1503).

示例

T1503
货号
-
25G
包装规格/数量

其它示例:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

输入内容 1.000309185)

遇到问题?欢迎随时联系我们技术服务 寻求帮助

批号可以在产品标签上"批“ (Lot或Batch)字后面找到。

Aldrich 产品

  • 如果您查询到的批号为 TO09019TO 等,请输入去除前两位字母的批号:09019TO。

  • 如果您查询到的批号含有填充代码(例如05427ES-021),请输入去除填充代码-021的批号:05427ES。

  • 如果您查询到的批号含有填充代码(例如 STBB0728K9),请输入去除填充代码K9的批号:STBB0728。

未找到您寻找的产品?

部分情况下,可能未在线提供COA。如果搜索不到COA,可在线索取。

索取COA

Masateru M Ito et al.
Nature, 570(7761), 363-367 (2019-06-21)
The formation of microscopic cavities and microfibrils at stress hotspots in polymers is typically undesirable and is a contributor to material failure. This type of stress crazing is accelerated by solvents that are typically weak enough not to dissolve the
Kinetic study on reactions between polymer chain-ends. Coupling reactions of living polystyrene with chloro-ended polystyrene.
Okamoto A, et al.
Eur. Polymer J., 18(6), 545-548 (1982)
Astrid Maruti et al.
Journal of chromatography. A, 1551, 41-51 (2018-04-14)
A novel extraction technique is proposed in which the Multiple Headspace Extraction (MHE) approach is used in conjunction with Headspace Sorptive Extraction (HSSE) and Gas Chromatography-Mass Spectrometry (GC-MS) detection. The extraction method was developed to determine volatile compounds in macroalgae.
K R Harikumar et al.
Chemical communications (Cambridge, England), 47(44), 12101-12103 (2011-10-19)
Chloropentane forms asymmetric ('A') and symmetric ('S') pairs on Si(100)-2×1, differing in the direction of curvature of one pentane tail. Surprisingly this renders the rate of thermal reaction of 'A' fifteen times greater than 'S' in chlorinating room-temperature silicon. Correspondingly
Maxwell Wei-Hao Li et al.
Journal of chromatography. A, 1620, 461002-461002 (2020-03-08)
Micro gas chromatography (µGC) is a technique developed for rapid, in situ analysis of volatile organic compounds (VOCs) for environmental protection, industrial monitoring, and toxicology. While reduced µGC size and power requirements allow for increased portability, the low moisture and

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门