Select a Size
About This Item
vapor density
3.9 (vs air)
Quality Segment
vapor pressure
97.5 mmHg ( 20 °C)
assay
≥99.0%
form
liquid
concentration
≥99,0%
technique(s)
HPLC: suitable, UV/Vis spectroscopy: suitable
impurities
<0.050% water
evapn. residue
<0.005%
refractive index
n
pH
1 (20 °C, 10 g/L)
bp
72.4 °C (lit.)
mp
−15.4 °C (lit.)
solubility
water: soluble
density
1.489 g/mL at 20 °C (lit.)
λ
H2O reference
UV absorption
λ: 260 nm Amax: 1.0, λ: 270 nm Amax: 0.10, λ: 280 nm Amax: 0.05, λ: 290 nm Amax: 0.04, λ: 300 nm Amax: 0.03, λ: 320 nm Amax: 0.025
application(s)
food and beverages
SMILES string
OC(C(F)(F)F)=O
InChI
1S/C2HF3O2/c3-2(4,5)1(6)7/h(H,6,7)
InChI key
DTQVDTLACAAQTR-UHFFFAOYSA-N
General description
Application
TFA can be added to aqueous and organic mobile phases, including commonly used HPLC solvent systems. The required concentration depends on the analyte, stationary phase, detector and method objective. Method developers should optimize the concentration experimentally and verify system suitability before routine use.
For UV-detected HPLC, impurities that absorb in the detector’s operating range can increase baseline absorbance or affect sensitivity. A defined UV absorbance specification helps to understand the intended quality profile of the reagent before method use.
Practical method considerations
- UV detection: Select the detection wavelength with the specified UV absorbance limits in mind. The product has defined limits at 260, 270, 280, 290, 300 and 320 nm; these limits are listed in the Features and benefits section.
- Gradient methods: TFA is suitable for use in aqueous/organic gradient systems when the method has been developed and qualified for the chosen composition and gradient profile.
- Peak shape and retention: TFA may improve the chromatographic behavior of some basic or ionizable analytes, but the effect is analyte- and method-dependent.
- Detector and MS compatibility: TFA is volatile, but it can reduce electrospray ionization response in LC-MS for some analytes. For MS-based methods, evaluate signal response and consider whether an alternative acidic modifier is more appropriate.
- System suitability: Confirm retention, resolution, peak shape, baseline behavior and detector response under the final method conditions.
- Mobile phase component in the estimation of chlorogenic acid and rutin in Rosaceae extracts by HPLC
- Solvent to extract rabbit plasma, followed by HPLC purification of plasma protein content
- Mobile phase solvent for separation of amino acids extracted from sediments, prior to HPLC analysis
Features and Benefits
The productspecification defines UV absorbance limits at the following wavelengths:
Wavelength Maximum UV absorbance
320 nm ≤ 0.025
300 nm ≤ 0.03
290 nm ≤ 0.04
280 nm ≤ 0.05
270 nm ≤ 0.10
260 nm ≤ 1.0
What these wavelength specifications mean
- The listed limits apply specifically to 260, 270,280, 290, 300 and 320 nm.
- The limits become more stringent at the longerwavelengths from 270 to 320 nm, supporting use in HPLC methods with detectionin those specified regions.
- The 260 nm limit is < 1.0, which is lessstringent than the limits specified at 270–320 nm. Users working close to 260nm should therefore account for the higher permitted absorbance when assessingbaseline and sensitivity.
- Performance at other wavelengths should be evaluated bythe user under the intended method conditions
- Defined HPLC quality: A specification tailoredto chromatographic reagent use.
- Controlled UV profile: Absorbance limits arestated at six named wavelengths rather than implied across an undefined UVrange.
- Low residue: Residue on evaporation is limitedto < 0.005%, helping reduce the risk of non-volatile contamination from thereagent.
- Controlled water content: Water is limited to< 0.05% by Karl Fischer analysis.
- High purity and consistent assay: GC purity is> 99.00 area % and titration assay is controlled to 99.00–101.00%.
- Clear expectations: The specificationidentifies the wavelengths and quality attributes within scope, helping usersselect the reagent for their HPLC method with appropriate expectations.
Still not finding the right product?
Explore all of our products under Trifluoroacetic acid
Signal Word
Danger
Storage Class
8A - Combustible corrosive hazardous materials
supp_hazards
Hazard Codes
Precautionary Statements
Hazard Classifications
Acute Tox. 4 Inhalation - Aquatic Chronic 3 - Eye Dam. 1 - Repr. 2 - Skin Corr. 1A
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.