Merck
CN
所有图片(1)

文件

安全信息

CDUFBI0A1

Milli-Q

Biopak 纯化柱

Ultrafilter for the production of pyrogen-, nuclease-, protease- and bacteria-free water at the point of dispense of Milli-Q® IQ/IX/EQ systems

登录查看公司和协议定价

别名:
Biopak®终端过滤器
eCl@ss:
33050190

物料

polysulfone filter

质量水平

包装

pkg of 1 unit

manufacturer/tradename

BioPak®

technique(s)

ELISA: suitable
PCR: suitable
cell culture | mammalian: suitable

相容性

for use with Milli-Q® EQ 7000
for use with Milli-Q® EQ 7008
for use with Milli-Q® EQ 7016
for use with Milli-Q® IX 7003
for use with Milli-Q® IX 7005
for use with Milli-Q® IX 7010
for use with Milli-Q® IX 7015
for use with Milli-Q® IQ 7000
for use with Milli-Q® IQ 7003
for use with Milli-Q® IQ 7005
for use with Milli-Q® IQ 7010
for use with Milli-Q® IQ 7015

运输

ambient

正在寻找类似产品? Visit 产品对比指南

一般描述

Biopak® Polisher 是一种超滤柱,设计用于以Milli-Q®纯化水生产适用于分子生物学、生物化学和细胞培养的水。经过验证,它可以连续使用90天。

应用

Biopak®精纯柱超滤装置适用于Milli-Q® IX 7003/05/10/15、Milli-Q® IQ 7000、Milli-Q® IQ 7003/05/10/15、Milli-Q® EQ 7000和Milli-Q® EQ 7008/16净水系统。 设计用于分子生物学、生物化学和细胞培养学(使用Milli-Q®纯净水时)等应用,Biopak®超滤装置可去除大分子和较大生物结构,例如细菌等。

Biopak® Polisher推荐用于各种需要控制细菌、热源、核酸酶和/或蛋白酶水平的实验室应用。
这包括小干扰RNA(siRNA)研究、RNA原位杂交、微阵列开发、或蛋白质合成机制的研究。

特点和优势

  • 最大限度降低核酸酶、蛋白酶、热原或细菌污染的风险。
  • 消除了对DEPC等有毒试剂的需求,从而提高安全性,节省时间并降低成本。
  • 底部尖端经重新设计,可安全地安装保护罩。
  • 易于维护:精纯柱易于安装替换;无需灭菌。
  • 用于将 RFID 与 POD 连接的 e-Sure 标签可在 POD 触摸屏界面上实现完全可追溯性(数据管理)和消耗状态自动监测。

其他说明

  • 热原(内毒素)< 0.001 EU/mL
  • RNA 酶 < 1 pg/mL
  • DNA酶 < 5 pg/mL
  • 蛋白酶 < 0.15 μg/mL
  • 细菌 < 0.01 CFU/mL

使用指南

  • 生物体存留:细菌和热原
  • 作用机制:超滤
  • 应用:细胞培养基、分子生物学
  • 预期用途:减少生物负荷
  • 使用说明:这一产品通过超滤中空纤维提供水过滤。请参阅产品包装插页“更换”部分。
  • 储存声明:干燥储存
  • 处置声明:根据国家、省市和当地适用法规处置。
Directions For Use
Organism Retention: Bacteria and pyrogens
Mode of Action: Ultrafiltration
Application: Cell culture media, molecular biology
Intended Use: Bioburden reduction
Instructions for Use: This item provides water filtered through ultrafiltration hollow fibers. Refer to insert, section "replacement" in the product package.
Storage Statement: Store in dry location.
Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

法律信息

BIOPAK is a registered trademark of Merck KGaA, Darmstadt, Germany
Milli-Q is a registered trademark of Merck KGaA, Darmstadt, Germany

储存分类代码

11 - Combustible Solids

法规信息

新产品

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

为方便起见,与您过往购买产品相关的文件已保存在文档库中。

访问文档库

难以找到您所需的产品或批次号码?

在网站页面上,产品编号会附带包装尺寸/数量一起显示(例如:T1503-25G)。请确保 在“产品编号”字段中仅输入产品编号 (示例: T1503).

示例

T1503
货号
-
25G
包装规格/数量

其它示例:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

输入内容 1.000309185)

遇到问题?欢迎随时联系我们技术服务 寻求帮助

批号可以在产品标签上"批“ (Lot或Batch)字后面找到。

Aldrich 产品

  • 如果您查询到的批号为 TO09019TO 等,请输入去除前两位字母的批号:09019TO。

  • 如果您查询到的批号含有填充代码(例如05427ES-021),请输入去除填充代码-021的批号:05427ES。

  • 如果您查询到的批号含有填充代码(例如 STBB0728K9),请输入去除填充代码K9的批号:STBB0728。

未找到您寻找的产品?

部分情况下,可能未在线提供COA。如果搜索不到COA,可在线索取。

索取COA

  1. How frequently do the various consumables need to be changed?

    The frequency that consumables must be changed depends on the system's usage (treated water volume) and on the consumables themselves (time of usage). In order to ensure the quality of water and your results, the consumables should be replaced when the system alerts you.

  2. What is the consumables delivery time?

    Refer to the consumable's Product page for a first estimation of its expected delivery time and contact customer service for more information.

  3. How are consumables changed?

    To help you to change your system's consumables, several video tutorials are available on our YouTube channel: Milli-Q®System Care Tutorials. For high-flow systems, please keep in mind that all consumable changes must be approved by a 3-digit code that only the person in charge of the system knows.

  4. What is the shelf life for Filter?

    The shelf life is 2 years for all consumables kept in the recommended storage conditions (temperatures from 5 to 30°C; humidity between 10 and 80%). Contact your local representative for more information.

  5. Can I arrange to have my consumables automatically ordered and delivered once a year?

    It's possible to place only one consumable order per year with a specific contract called "Consumable Supply Agreement (CSA)" For further information, contact your local representative or sales contact.

  6. Where can I find data sheets, Certificates of Origin, Certificates of Analysis, and Certificates of Quality?

    Documents and certificates are available in the "Documentation" section on this page. Do not hesitate to contact us if you require further information.

  7. What steps are you taking towards improved sustainability?

    Sustainability is at the heart of our innovations. From reducing water and energy consumption, to minimizing plastic and chemical waste, our dedicated water system engineers are constantly working on new ways to reduce the ecological footprint of our products to better support the sustainability goals we’re all striving towards. For more information, we invite you to review the following brochure and infographic which highlight our efforts and achievements: link. Do not hesitate to contact your local representative for further information.

  8. How can I know which consumables can be used with my system?

    To know which consumables can be used on your system, you can see in the user manual of you system or see it on the following webpage of consumables. All the consumables for each system are indicated.

  9. If I have a final filter that I use only occasionally (e.g., Biopak®) and have another filter (e.g. Millipak®) that I most of the time, can I keep the 'occasional-use' filter for use again at a later time?

    It is not possible to re-use a filter that has been used and then removed because air intake during replacement creates an airlock and blocks water passing through the filter. If you regularly need two different filters, we recommend using two POD dispensers.

  10. Can consumables be opened and refilled?

    Unfortunately, this is not possible because of safety issues and the need to guarantee the quality of consumables and their interior purification components. Our consumables are manufactured in an ISO 9001-certified facility France in agreement with high quality standards.

Whole mount RNA-FISH on ovules and developing seeds
Bleckmann A and Dresselhaus T
Chemosphere, 159-171 (2017)
Ryo Iizuka et al.
Methods in molecular biology (Clifton, N.J.), 1368, 53-65 (2015-11-29)
Extracellular microRNAs (miRNAs) in body fluids have been identified as promising biomarkers for different human diseases. The high-throughput, multiplexed detection and quantification of these miRNAs are highly beneficial for the rapid and accurate diagnosis of diseases. Here, we developed a
Gabriel Rosenblum et al.
Nucleic acids research, 40(12), e88-e88 (2012-03-17)
We present a flexible, real-time-coupled transcription-translation assay that involves the continuous monitoring of fluorescent Emerald GFP formation. Along with numerical simulation of a reaction kinetics model, the assay permits quantitative estimation of the effects on full-length protein synthesis of various
Real-time assay for testing components of protein synthesis
Rosenblum G, et al.
Nucleic Acids Research, 40(12), e88-e88 (2012)
Graphene oxide size and oxidation degree govern its supramolecular interactions with siRNA
Reina G, et al.
Nanoscale, 10(30), 5965-5974 (2018)

商品

An ultrafiltration cartridge can be placed at the outlet of a water purification system to deliver nuclease-free ultrapure water.

Learn how water impurities can affect PCR and related methodologies. High purity water purified using ultrafiltration is suitable for PCR and related techniques.

Endocrine disruptors such as BPA can interfere with embryological development. This study shows ultrapure water from a Milli-Q® lab water system to be free of detectable BPA and thus suitable for embryology research.

Nuclease-free water (or PCR water) is needed in molecular biology to avoid sample degradation during PCR, sequencing, etc. Ultrafiltration provides a quicker, safer, and more sustainable alternative to DEPC treatment when preparing RNase-free and DNase-free water.

相关内容

Freshly purified ultrapure water is recommended for electrophysiology assays. Using an ultrafiltration cartridge (Biopak®) at the of use of the water system eliminates risk of bacteria and endotoxin contamination that can negatively impact such techniques.

Milli-Q®超纯水始终为您的科研工作注入信心。探索我们的扩展型系统以了解实验室纯水解决方案如何全面满足您的需求并突破实验室瓶颈。

Always have confidence in your science with Milli-Q® ultrapure water. Discover our expanded system offer to find the lab water solution that fully satisfies your lab’s needs and constraints.

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门