Merck
CN

34851

Sigma-Aldrich

乙腈

suitable for HPLC, gradient grade, ≥99.9%

登录查看公司和协议定价

别名:
ACN, 乙腈, 氰甲烷, 甲基氰
线性分子式:
CH3CN
CAS号:
分子量:
41.05
Beilstein:
741857
EC 号:
MDL编号:
eCl@ss:
39031501
PubChem化学物质编号:
NACRES:
NA.03

等级

gradient grade

质量水平

蒸汽密度

1.41 (vs air)

蒸汽压

72.8 mmHg ( 20 °C)

检测方案

≥99.9%

形式

liquid

自燃温度

973 °F

expl. lim.

16 %

baseline drift measuring range

≤15 mAU (210 nm)

技术

HPLC: suitable

杂质

≤0.0002% free alkali (as NH3)
≤0.0005% non-volatile matter
≤0.001% free acid (as CH3COOH)
≤0.02% water (Karl Fischer)
≤0.5 ppb fluorescence (quinine) at 365 nm
≤1 ppb fluorescence (quinine) at 254 nm

折射率

n20/D 1.344 (lit.)

bp

81-82 °C (lit.)

mp

−45 °C (lit.)

密度

0.786 g/mL at 25 °C (lit.)

HPLC-梯度

≤0.5 mAU at 254 nm
≤3 mAU at 210 nm

紫外吸收

λ: 195 nm Amax: ≤0.12
λ: 200 nm Amax: ≤0.032
λ: 230 nm Amax: ≤0.0044
λ: 235 nm Amax: ≤0.0044
λ: 250 nm Amax: ≤0.0044
λ: 400 nm Amax: ≤0.0044

应用

food and beverages

格式

neat

储存温度

room temp

SMILES字符串

CC#N

InChI

1S/C2H3N/c1-2-3/h1H3

InChI key

WEVYAHXRMPXWCK-UHFFFAOYSA-N

正在寻找类似产品? Visit 产品对比指南

一般描述

乙腈(MeCN)在多项泛被用作溶剂,并具有较高的介电常数(37.5)。各种获得不同等级的乙腈用于不同研究(极谱法,光谱学等)多种不同的纯化过程已被许多研究人员所报道。

应用

乙腈(MeCN)可作为萃取溶剂用于水果和蔬菜中农药残留物的定量。

制备说明

产品经0.2 μm滤器过滤

其他说明

重要通知
  • 货号 34851-4X2.5L的产品即将停产。请订购34851-2.5L单瓶装,因为其具体参数与上述产品本质相同。
  • 货号34851-6X1L的产品即将停产。请订购34851-1L单瓶装,因为其物理参数与上述产品本质相同。

推荐产品

探索最适于 HPLCLC-MS 分析的 LiChropur 试剂

法律信息

Pure-Pac is a registered trademark of Merck KGaA, Darmstadt, Germany

象形图

FlameExclamation mark

警示用语:

Danger

危险分类

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2

储存分类代码

3 - Flammable liquids

WGK

WGK 2

闪点(°F)

35.6 °F - closed cup

闪点(°C)

2.0 °C - closed cup

法规信息

危险化学品

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

为方便起见,与您过往购买产品相关的文件已保存在文档库中。

访问文档库

难以找到您所需的产品或批次号码?

在网站页面上,产品编号会附带包装尺寸/数量一起显示(例如:T1503-25G)。请确保 在“产品编号”字段中仅输入产品编号 (示例: T1503).

示例

T1503
货号
-
25G
包装规格/数量

其它示例:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

输入内容 1.000309185)

遇到问题?欢迎随时联系我们技术服务 寻求帮助

批号可以在产品标签上"批“ (Lot或Batch)字后面找到。

Aldrich 产品

  • 如果您查询到的批号为 TO09019TO 等,请输入去除前两位字母的批号:09019TO。

  • 如果您查询到的批号含有填充代码(例如05427ES-021),请输入去除填充代码-021的批号:05427ES。

  • 如果您查询到的批号含有填充代码(例如 STBB0728K9),请输入去除填充代码K9的批号:STBB0728。

未找到您寻找的产品?

部分情况下,可能未在线提供COA。如果搜索不到COA,可在线索取。

索取COA

  1. Which document(s) contains shelf-life or expiration date information for a given product?

    If available for a given product, the recommended re-test date or the expiration date can be found on the Certificate of Analysis.

  2. How do I get lot-specific information or a Certificate of Analysis?

    The lot specific COA document can be found by entering the lot number above under the "Documents" section.

  3. How do I find price and availability?

    There are several ways to find pricing and availability for our products. Once you log onto our website, you will find the price and availability displayed on the product detail page. You can contact any of our Customer Sales and Service offices to receive a quote.  USA customers:  1-800-325-3010 or view local office numbers.

  4. What is the Department of Transportation shipping information for this product?

    Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product. 

  5. What is the flash point of Acetonitrile, Product 34851?

    The flash point is 2.0°C. 

  6. What is the surface tension of Acetonitrile, Product 34851?

    The surface tension is 29.04 dynes/cm at 20°C, according to the chemicals encyclopedia published by the Royal Society of Chemistry, 12th ed., Entry# 68.

  7. What is the viscosity of Acetonitrile, Product 34851?

    The viscosity is 0.38 cP at 15°C.

  8. My question is not addressed here, how can I contact Technical Service for assistance?

    Ask a Scientist here.

Purification of acetonitrile.
Walter M and Ramaley L.
Analytical Chemistry, 45(1), 165-166 (1973)
Michelangelo Anastassiades et al.
Journal of AOAC International, 86(2), 412-431 (2003-05-02)
A simple, fast, and inexpensive method for the determination of pesticide residues in fruits and vegetables is introduced. The procedure involves initial single-phase extraction of 10 g sample with 10 mL acetonitrile, followed by liquid-liquid partitioning formed by addition of
Timo Glatter et al.
Molecular systems biology, 5, 237-237 (2009-01-22)
Protein complexes represent major functional units for the execution of biological processes. Systematic affinity purification coupled with mass spectrometry (AP-MS) yielded a wealth of information on the compendium of protein complexes expressed in Saccharomyces cerevisiae. However, global AP-MS analysis of
Elke H J Krekels et al.
Clinical pharmacokinetics, 53(6), 553-563 (2014-02-06)
From a previously validated paediatric population pharmacokinetic model, it was derived that non-linear morphine maintenance doses of 5 μg/kg(1.5)/h, with a 50 % dose reduction in neonates with a postnatal age (PNA) <10 days, yield similar morphine and metabolite concentrations
Hélène Hall et al.
Brain : a journal of neurology, 137(Pt 9), 2493-2508 (2014-07-27)
The neuropathological substrate of dementia in patients with Parkinson's disease is still under debate, particularly in patients with insufficient alternate neuropathology for other degenerative dementias. In patients with pure Lewy body Parkinson's disease, previous post-mortem studies have shown that dopaminergic

商品

A shortened review of fundamentals of Porous Graphitic Carbon (PGC) materials. What they are and how do they work as a stationary phase material in HPLC?.

A step-by-step workflow for the sample preparation of hemp bud, hemp oil, chocolate, gummy, candy, and cream for the HPLC-PDA separation and analysis of 17 cannabinoids.

Polar graphitic carbon (2.7 μm) based Ultra/High-performance liquid chromatographic separation of four highly polar pesticides, two polar herbicides―paraquat & diquat, and Vitamin D and its metabolites.

Substances are said to be miscible in one another if they dissolve to form a uniform solution. Bookmark or download our miscibility table for common lab solvents.

实验方案

HPLC Analysis of the Monoclonal Antibody (mAb) Erbitux (Cetuximab) on BIOshell™ A400 Protein C4

相关内容

ZipTip® micro-SPE pipette tips are used as a single-step desalting, concentration, and purification tool for complex samples before mass spec analyses.

Chromatograms

application for HPLC

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门