Sign In to View Organizational & Contract Pricing.
Select a Size
Change View
About This Item
Linear Formula:
H2C=CHCO2(CH2)5CH3
CAS Number:
Molecular Weight:
156.22
NACRES:
NA.23
PubChem Substance ID:
UNSPSC Code:
12162002
EC Number:
219-698-5
MDL number:
Quality Level
assay
98%
form
liquid
contains
100 ppm hydroquinone as inhibitor
refractive index
n20/D 1.428 (lit.)
bp
88-90 °C/24 mmHg (lit.)
density
0.888 g/mL at 25 °C (lit.)
SMILES string
CCCCCCOC(=O)C=C
InChI
1S/C9H16O2/c1-3-5-6-7-8-11-9(10)4-2/h4H,2-3,5-8H2,1H3
InChI key
LNMQRPPRQDGUDR-UHFFFAOYSA-N
General description
Poly(hexyl acrylate-co-1,4-butanediol diacrylate-co-[2-(acryloyloxy)ethyl]trimethyl ammonium chloride) can be prepared by the photopolymeirzation of hexyl acrylate and several other components. These polyacrylate-based monolithics were designed to be used for capillary electrochromatography (CEC). Mutagenicity of this acrylate ester was evaluated by the Salmonella-microsome test.
signalword
Warning
hcodes
Hazard Classifications
Aquatic Acute 1 - Aquatic Chronic 1 - Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1B - STOT SE 3
target_organs
Respiratory system
Storage Class
10 - Combustible liquids
flash_point_f
154.4 °F - closed cup
flash_point_c
68 °C - closed cup
ppe
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Braden L Leigh et al.
ACS applied materials & interfaces, 9(37), 31488-31496 (2017-08-26)
Cochlear Implants (CIs) suffer from limited tonal resolution due, in large part, to spatial separation between stimulating electrode arrays and primary neural receptors. In this work, a combination of physical and chemical micropatterns, formed on acrylate polymers, are used to
Non-mutagenicity of 27 aliphatic acrylate esters in the Salmonella-microsome test
Waegemaekers THJM, et al.
Mutation Research. Genetic Toxicology and Environmental Mutagenesis, 137(2-3), 95-102 (1984)
Violaine Augustin et al.
Electrophoresis, 29(18), 3875-3886 (2008-10-14)
A polyacrylate-based monolithic column bearing cationic functionalities and designed for capillary electrochromatography (CEC) has been prepared via photopolymerization of a mixture of hexyl acrylate, butanediol diacrylate, 2-(acryloyloxy) ethyltrimethyl ammonium chloride (monomers), azobisisobutyronitrile (photoinitiator), acetonitrile, phosphate buffer, and ethanol (porogens). The
Global Trade Item Number
| SKU | GTIN |
|---|---|
| 408905-25ML | 04061837405877 |
| 408905-100ML | 04061831988758 |

