Sign In to View Organizational & Contract Pricing.
Select a Size
About This Item
Linear Formula:
[-(CH2)4CO2CH2CH(C2H5)(CH2)3CH3]2
CAS Number:
Molecular Weight:
426.67
UNSPSC Code:
12352100
NACRES:
NA.22
PubChem Substance ID:
EC Number:
204-558-8
Beilstein/REAXYS Number:
1806504
MDL number:
Assay:
≥97.0% (GC)
Form:
liquid
InChI key
VJHINFRRDQUWOJ-UHFFFAOYSA-N
InChI
1S/C26H50O4/c1-5-9-17-23(7-3)21-29-25(27)19-15-13-11-12-14-16-20-26(28)30-22-24(8-4)18-10-6-2/h23-24H,5-22H2,1-4H3
SMILES string
CCCCC(CC)COC(=O)CCCCCCCCC(=O)OCC(CC)CCCC
assay
≥97.0% (GC)
form
liquid
refractive index
n20/D 1.450 (lit.)
bp
212 °C/1 mmHg (lit.)
density
0.914 g/mL at 25 °C (lit.)
functional group
ester
Quality Level
Looking for similar products? Visit Product Comparison Guide
Related Categories
Application
Bis(2-ethylhexyl) sebacate is commonly used as a pressure transmitting fluid (PTF) in hydraulically operated devices, pressure measuring instruments and hydraulic pressure balances. It is also a plasticizing solvent mediator for preparing poly(vinyl chloride) (PVC) based membranes.
Storage Class
10 - Combustible liquids
wgk
awg
ppe
Eyeshields, Gloves
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Experimental density and viscosity measurements of di (2ethylhexyl) sebacate at high pressure.
Paredes X, et al.
The Journal of Chemical Thermodynamics, 44(1), 38-43 (2012)
Determination of complex formation constants of 18 neutral alkali and alkaline earth metal ionophores in poly (vinyl chloride) sensing membranes plasticized with bis (2-ethylhexyl) sebacate and o-nitrophenyloctylether.
Qin Y, et al.
Analytica Chimica Acta, 421(2), 207-220 (2000)
Kevin R Wilson et al.
Physical chemistry chemical physics : PCCP, 14(4), 1468-1479 (2011-12-14)
The heterogeneous reactions of hydroxyl radicals (OH) with squalane and bis(2-ethylhexyl) sebacate (BES) particles are used as model systems to examine how distributions of reaction products evolve during the oxidation of chemically reduced organic aerosol. A kinetic model of multigenerational
Agata Michalska et al.
Analytical chemistry, 78(15), 5584-5589 (2006-08-02)
Laser ablation inductively coupled plasma mass spectrometry was used to evaluate ion depth profiles across ion-selective membranes. Advantageously, this approach does not require incorporation of additional components (e.g., chromoionophore) in the membrane composition, as compared to that used in typical
F J Wilson et al.
Journal of applied physiology (Bethesda, Md. : 1985), 58(1), 223-229 (1985-01-01)
Theoretical models of particle deposition in the respiratory tract predict high fractional deposition for particles of less than 0.1 micron, but there are few confirming experimental data for those predictions. We have measured the deposition fraction of a nonhygroscopic aerosol
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service