Select a Size
About This Item
Product Name
SMC® Glucagon High Sensitivity Immunoassay Kit, Used for ultrasensitive quantification of Glucagon in human, rat or mouse plasma
product line
SMC®
usage
kit sufficient for 96 wells
quality
200
species reactivity
human, mouse, rat
manufacturer/tradename
SMC®
technique(s)
single molecule counting: suitable
input
plasma (K2 EDTA)
UniProt accession no.
compatibility
for use with FemtoQuest™ and SMCxPRO® instruments
shipped in
wet ice
storage temp.
2-8°C
Disclaimer
Legal Information
Analysis Note
Endocrinology
- Sensitivity: LLOQ 781 fg/mL* (SMCxPRO® Instrument)
- Standard Curve Range: 200-200,000 fg/mL
- Intra-assay CV: <15%
- Inter-assay CV: <20%
- Linearity: Plasma: 86%
- Recovery: Plasma: 86%
- *Indicative LLOQ created from average of 14 independent in house runs,where >80% met same value defined with CV & Recovery +/- 20%. Refer toCoA for lot specific performance.
Application
Biochem/physiol Actions
Oxyntomodulin (human) was found to be <0.5% detectable.
GLP-1 (human) was not found to be detectable.
GLP-2 (human) was not found to be detectable.
GIP (human) was not found to be detectable.
Features and Benefits
- Ultra-Sensitive Detection — Quantifies glucagon down to 0.20 pg/mL
- Wide Dynamic Range — Covers 0.20–200 pg/mL
- SMC® Technology — Enables single molecule resolution for precise quantification
- Species Compatibility — Validated for human, mouse, and rat plasma
- Detect Glucagon at Femto-Level Sensitivity — Ideal for metabolic and endocrine research
- Reliable Across Species — Supports translational studies from animal models to human samples
- Accurate Results with Minimal Interference — Trusted data in complex biological fluids
Packaging
General description
Altered glucagon levels are associated with metabolicdisorders such as type 2 diabetes, obesity, and insulin resistance. Accuratemeasurement of glucagon is essential for understanding pancreatic function,evaluating therapeutic interventions, and studying the hormonal regulation ofenergy metabolism.
signalword
Danger
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Irrit. 2 - Repr. 1B - STOT RE 2 Inhalation
target_organs
Respiratory Tract
Storage Class
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Regulatory Information
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Related Content
Explore ultrasensitive immunoassay technology with SMC® technology, including its biomarker detection platform, advantages of high sensitivity assays, and more.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service