Skip to Content
Merck
CN

8.21177

Trimethylamine

(40% solution in water) for synthesis

Synonym(s):

N,N,N-Trimethylamine, N,N-Dimethylmethanamine

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View

About This Item

NACRES:
NA.22
UNSPSC Code:
12352116
Form:
liquid
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


vapor pressure

600 hPa ( 20 °C)

Quality Segment

form

liquid

autoignition temp.

250 °C

potency

500 mg/kg LD50, oral (Rat)

expl. lim.

2-11.6 % (v/v) anhydrous substance()

pH

13 (20 °C in H2O)

bp

30.8 °C

mp

-2 °C

transition temp

flash point -45 °C

density

0.88 g/cm3 at 20 °C

storage temp.

2-30°C

Application


  • Blood trimethylamine-N-oxide origins: Explores the microbiota-mediated breakdown of phosphatidylcholine and absorption from the small intestine, significant for drug discovery in cardiovascular diseases (Stremmel et al., 2017).

  • Diabetes and trimethylamine N-oxide levels: Discusses the strong associations between systemic trimethylamine N-oxide levels and diabetes, offering insights into potential therapeutic targets for drug discovery (Dambrova et al., 2016).

  • Detection via lanthanide metal-organic framework: Trimethylamine-N-oxide detection using a lanthanide MOF, critical for advancing sensor technology in material science (Min et al., 2022).

  • Trimethylamine N-Oxide research: Overview of trimethylamine N-oxide′s roles, focusing on dietary sources and health implications, valuable for academia and nutritional studies (Velasquez et al., 2016).

  • Efficient gas sensors: Application of MoS2/SnO2 heterojunctions in creating effective gas sensors for trimethylamine, useful in material science for developing new sensor technologies (Qiao et al., 2018).


Analysis Note

Assay (acidimetric): 38.0 - 41.0 %


Still not finding the right product?

Explore all of our products under Trimethylamine


signalword

Danger

Hazard Classifications

Acute Tox. 4 Oral - Eye Dam. 1 - Flam. Liq. 1 - Skin Corr. 1 - STOT SE 3

target_organs

Respiratory system

Storage Class

3 - Flammable liquids

wgk

WGK 1

flash_point_f

-49.0 °F

flash_point_c

-45 °C



Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library