MILLIPLEX® Equine Cytokine/Chemokine Panel

Bulk (Space Saver) Premixed Equine Cyokine/Chemokine 23-Plex Panel

Synonym(s):

Equine cytokine panel, Luminex equine cytokine multiplex kit, Millipore horse cytokine kit, horse inflammation assay

Sign In to View Organizational & Contract Pricing.

Select a Size


About This Item

UNSPSC Code:
12161503
NACRES:
NA.47
eCl@ss:
32161000
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

Product Name

MILLIPLEX® Equine Cytokine/Chemokine Panel,

species reactivity

horse

Quality Level

description

Bulk (Space Saver) Premixed Equine Cyokine/Chemokine 23-Plex Panel

assay range

accuracy: 82%
(G-CSF), accuracy: 83%
(IFNγ), accuracy: 85%
(IL-13), accuracy: 86%
(IP-10), accuracy: 87%
(TNFα), accuracy: 88%
(IL-1β), accuracy: 88%
(RANTES/CCL5), accuracy: 89%
(IL-1α), accuracy: 89%
(IL-8/CXCL8), accuracy: 92%
(IL-5), sensitivity: 1.4 pg/mL
(IL-6), sensitivity: 10.6 pg/mL
(IL-5), sensitivity: 13.5 pg/mL
(IL-2), sensitivity: 15.4 pg/mL
(IL-17A), sensitivity: 16.3 pg/mL
(FGF-2), sensitivity: 16.7 pg/mL
(IP-10), sensitivity: 165 pg/mL
(IFNγ), sensitivity: 25.3 pg/mL
(IL-18), sensitivity: 29.3 pg/mL
(IL-1β), sensitivity: 3.9 pg/mL
(RANTES/CCL5), sensitivity: 3.94 pg/mL
(GM-CSF), sensitivity: 340 pg/mL
(G-CSF), sensitivity: 355 pg/mL
(IL-4), sensitivity: 39-130 pg/mL
(IL-13), sensitivity: 39.1 pg/mL
(IL-1α), sensitivity: 399 ng/mL
(MCP-1), sensitivity: 457 pg/mL
(Fractalkine/CS3CL1), sensitivity: 49.2 pg/mL
(IL-12 (p70)), sensitivity: 5.2 pg/mL, sensitivity: 62.5 pg/mL
(IL-10), sensitivity: 7.8 pg/mL
(GRO), sensitivity: 74.3 pg/mL
(IL-8/CXCL8), sensitivity: 8.3 pg/mL
(Eotaxin/CCL11), standard curve range: 15-15,000 pg/mL
(IL-17A), standard curve range: 15-15,000 pg/mL
(IL-2), standard curve range: 15-15,000 pg/mL
(IL-5), standard curve range: 15-15,000 pg/mL
(IL-6), standard curve range: 15-15,000 pg/mL
(IP-10), standard curve range: 24-25,000 pg/mL
(FGF-2), standard curve range: 29-30,000 pg/mL
(IL-1β), standard curve range: 293-300,000 pg/mL
(IL-4), standard curve range: 34-35,000 pg/mL
(IL-18), standard curve range: 342-350,000 ng/mL
(MCP-1), standard curve range: 39-40,000 pg/mL
(IL-12 (p70)), standard curve range: 39-40,000 pg/mL
(IL-13), standard curve range: 4-4,000 pg/mL
(TNFα), standard curve range: 488-500,000 pg/mL
(IFNγ), standard curve range: 49-50,000 pg/mL
(IL-10), standard curve range: 5-5,000 pg/mL
(GM-CSF), standard curve range: 5-5,000 pg/mL
(RANTES/CCL5), standard curve range: 586-600,000 pg/mL
(Fractalkine/CS3CL1), standard curve range: 59-60,000 pg/mL
(IL-1α), standard curve range: 59-60,000 pg/mL
(IL-8/CXCL8), standard curve range: 6-6,000 pg/mL
(GRO), standard curve range: 7-7,000 pg/mL
(Eotaxin/CCL11), standard curve range: 78-80,000 pg/mL
(G-CSF)

technique(s)

multiplexing: suitable

input

serum plasma (Cell culture, cell culture supernatants)

packaging

pkg of 1 ea

manufacturer/tradename

Milliplex®

detection method

fluorometric (Luminex® xMAP® technology)

shipped in

wet ice

storage temp.

2-8°C

Looking for similar products? Visit Product Comparison Guide

General description

Researching horse cytokines and chemokines is pivotal for advancing our understanding of equine immunology and the underlying mechanisms of various diseases. By investigating the roles and interactions of these signaling molecules, scientists can uncover critical insights into inflammatory processes, immune responses, and the pathophysiology of equine conditions. This knowledge not only enhances our fundamental understanding of equine biology but also drives the development of targeted therapeutic strategies and interventions in equine medicine.

Application

MILLIPLEX® Qualified assays undergo rigorous assay development, verification, and Quality Control testing to achieve optimal performance. Simultaneously analyze 23 analytes in equine serum, plasma, and cell culture supernatants.

Analytes included: Eotaxin/CCL11, FGF-2, Fractalkine/CX3CL1, G-CSF, GM-CSF, GRO/KC, IFN-γ, IL-1α, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-8, IL-10, IL-12 (p70), IL-13, IL-17A, IL-18, IP-10 (CXCL10), MCP-1, RANTES (CCL5), TNF-α

Assay Characteristics: Refer to kit protocol for assay cross-reactivity, sensitivity, precision, and accuracy.

Features and Benefits

  • Flexible Incubation Options: Choose between a 2-hour room temperature protocol for rapid results or an overnight incubation at 2-8°C for increased sensitivity, accommodating various laboratory workflows and experimental timelines.
  • Comprehensive Inflammatory Disease Investigation: Monitor both pro-inflammatory and anti-inflammatory cytokines simultaneously, enabling researchers to dissect complex immune interactions and assess the overall health and inflammatory status of equine subjects.
  • Cost-Effective Multiplex Analysis: Replace multiple individual ELISAs with a single comprehensive panel, reducing reagent costs and sample consumption while providing more robust data from each assay.
  • Premixed Beads For Convenience: The ready-to-use bead cocktail eliminates the need for individual bead preparation, reducing hands-on time and minimizing pipetting errors, ensuring consistent results across all wells.

Legal Information

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Disclaimer

For research use only. Not for use in diagnostic procedures.

Label License/Sticker for Assay Product:

By opening the packaging containing this Assay Product (which contains fluorescently labeled microsphere beads authorized by Luminex Corporation) or using this Assay Product in any manner, you are consenting and agreeing to be bound by the End User Terms and Conditions and the End User License Agreement available at http://support.diasorin.com/end-user-terms-and-conditions/. If you do not agree to all of the terms and conditions, you must promptly return this Assay Product for a full refund prior to using it in any manner.

signalword

Danger

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

target_organs

Respiratory Tract

Storage Class

10 - Combustible liquids

wgk

WGK 3

Regulatory Information

新产品
This item has

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service