Product Name
Millipore Express® SHC, Opticap® XLT Capsule, Opticap® XLT, sterile, cartridge nominal length 20 in. (50 cm), filter diam. 10.7 cm (4.2 in.)
sterility
sterile
material
polyester support
polypropylene housing
polypropylene vent cap
silicone seal
polyethersulfone membrane
silicone O-ring
cartridge nominal length
20 in. (50 cm)
Quality Level
reg. compliance
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterilization compatibility
autoclavable compatible
product line
Opticap® XLT
feature
hydrophilic
manufacturer/tradename
Millipore Express®
parameter
1 bar max. differential pressure (15 psi) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.1 bar max. differential pressure (30 psi) at 25 °C (Reverse; intermittent)
2.8 bar max. inlet pressure (40 psi) at 60 °C
5.5 bar max. differential pressure (80 psi) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
6.9 bar max. differential pressure (100 psi) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
technique(s)
sterile filtration: suitable
L
62.5 cm (24.6 in.)
device size
20 in.
filter diam.
10.7 cm (4.2 in.)
filter filtration area
1.08 m2 (11.6 ft2)
impurities
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
matrix
Millipore Express® SHC
pore size
0.5/0.2 μm pore size
bubble point
≥4000 mbar (58 psig), air with water at 23 °C
fitting
38 mm (1 1/2 in.) inlet sanitary flange
38 mm (1 1/2 in.) outlet sanitary flange
Looking for similar products? Visit Product Comparison Guide
Analysis Note
General description
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Packaging
Preparation Note
3 autoclave cycles of 60 min at 126 °C; capable of 45 kilogray (4.5 Megarad) gamma exposure; not in-line steam sterilizable
Legal Information
Regulatory Information
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service