MXRDP2KT01

Millipore

Milliflex® Rapid System 2.0

for use with Milliflex Oasis®, suitable for bioburden testing, sterility testing

Sign Into View Organizational & Contract Pricing

AC/DC input

100 V / 230 V, 50-60 Hz

Agency

EP 2.6.1
USP 71
71

product line

Milliflex®

packaging

pkg of 1 kit

parameter

10 kg operating weight (22 lb) (Autospray Station)
5 kg operating weight (11 lb) (Detection Tower)

technique(s)

Rapid Sterility Testing: suitable

H × W × D

31 cm (12 in.) × 21 cm (8 in.) × 40 cm (16 in.), Auto Spray Station
35 cm (14 in.) × 30 cm (12 in.) × 13 cm (5 in.), Detection Tower

application(s)

bioburden testing
sterility testing

pharmaceutical
water monitoring

compatibility

for use with Milliflex Oasis®

General description

Milliflex® Rapid 2.0 Kit is an automated solution for rapid detection, imaging, and quantification of viable microbes in filterable solutions.
The detection method is based on highly sensitive ATP bioluminescence technology. The ATP method is regulatory compliant, highly reliable, and consistent with the detection rates matching the standards of current compendial testing methods.
The conventional way of visual evaluation is replaced by Complementary Metal Oxide Semiconductor (CMOS) in Milliflex® Rapid system. The state-of-the-art image analysis and optimized reagents require reduced incubation time for viable microbial detection.
The image analysis software intensifies (~1000 times) the bioluminescence from each microbial micro-colony and captures the light signals emitted by the microbes. The software enumerates the colonies and displays results as CFU (colony forming unit).

Application

Milliflex® Rapid 2.0 system is a perfect rapid solution used for bioburden and sterility testing. The system is compatible with a wide range of filterable samples from pharmaceutical, beverage, and personal care industries.

Features and Benefits

Milliflex® Rapid 2.0 system has the following features and benefits:
  • Consistent, fast, and reproducible results.
  • Correlation of CFU counts with that of traditional methods.
  • Data Integrity Software compliant with 21 CFR Part 11.
  • Easy Handling and Validation.

Components

Milliflex® Rapid 2.0 Kit includes the following components:
  • Detection Tower -MXRDP2DT00)
  • Auto Spray station - MXRP2SPRKT
  • 2 x Power Supplies required (not included, sold separately, region specific under MXRPWRSP--)

Other Notes

Download the Milliflex® Rapid System 2.0 software from here.

Legal Information

MILLIFLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIFLEX OASIS is a registered trademark of Merck KGaA, Darmstadt, Germany

related product

Product No.
Description
Pricing

Regulatory Information

新产品

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Related Content

The automated Milliflex® Rapid system can get you bioburden testing and sterility testing results days earlier. Its proven technology rapidly and accurately detects microorganisms in sterility, bioburden, in-process and product release testing.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service