Skip to Content
Merck
CN

36902

PCB No 101 solution

10 μg/mL in isooctane, analytical standard

Synonym(s):

2,2′,4,5,5′-Pentachlorobiphenyl solution, 2,2′,4,5,5′-PCB

Sign In to View Organizational & Contract Pricing.

Select a Size


About This Item

Empirical Formula (Hill Notation):
C12H5Cl5
CAS Number:
Molecular Weight:
326.43
EC Number:
208-759-1
UNSPSC Code:
41116107
NACRES:
NA.24
PubChem Substance ID:
MDL number:
Beilstein/REAXYS Number:
2507418
Ballschmiter Number:
101
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

Product Name

PCB No 101 solution, 10 μg/mL in isooctane, analytical standard

InChI key

LAHWLEDBADHJGA-UHFFFAOYSA-N

InChI

1S/C12H5Cl5/c13-6-1-2-9(14)7(3-6)8-4-11(16)12(17)5-10(8)15/h1-5H

SMILES string

Clc1ccc(Cl)c(c1)-c2cc(Cl)c(Cl)cc2Cl

grade

analytical standard

shelf life

limited shelf life, expiry date on the label

concentration

10 μg/mL in isooctane

technique(s)

HPLC: suitable
gas chromatography (GC): suitable

application(s)

environmental

format

single component solution

storage temp.

2-8°C

Quality Level

Application

Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

signalword

Danger

Hazard Classifications

Aquatic Acute 1 - Aquatic Chronic 1 - Asp. Tox. 1 - Flam. Liq. 2 - Skin Irrit. 2 - STOT SE 3

target_organs

Central nervous system

Storage Class

3 - Flammable liquids

wgk

WGK 2

flash_point_f

39.2 °F - closed cup

flash_point_c

4 °C - closed cup

ppe

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter

Regulatory Information

监管及禁止进口产品
This item has

Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Britt-Marie Bäcklin et al.
Toxicological sciences : an official journal of the Society of Toxicology, 75(1), 154-160 (2003-06-14)
Gray seal females living in the Baltic Sea have been found to exhibit a high prevalence of uterine leiomyomas. These animals are also known to accumulate lipid-soluble PCBs in their blubber. PCBs have documented endocrine-disrupting effects; to investigate whether the
Joseph E McGraw et al.
Biochemical and biophysical research communications, 344(1), 129-133 (2006-04-18)
Polychlorinated biphenyl IUPAC# 101-PCB 101 (chlorination pattern-2,2',4',5,5') is a common, persistent non-coplanar PCB congener found in the ambient environment but information related to its metabolism in humans is lacking. Previous studies indicate PCB 101 is rapidly metabolized in mammals through
Na He et al.
Chemosphere, 76(11), 1491-1497 (2009-07-15)
The reductive dechlorination and biodegradation of 2,2(')4,5,5(')-pentachlorobiphenyl (PCB#101) was investigated in a laboratory-scale. Palladium coated iron (Pd/Fe) was used as a catalytic reductant for the chemical degradation of 2,2(')4,5,5(')-pentachlorobiphenyl, and an aerobic bacteria was used for biodegradation following the chemical
Moazzam A Khan et al.
Toxicology letters, 144(2), 173-182 (2003-08-21)
Polychlorinated biphenyl compounds (PCBs) are global environmental contaminants that cause disruption of the endocrine system in humans and wildlife. Recently, we reported that acute exposures to ortho-PCB congeners 95 (2,3,6-2',5') or 101 (2,4,5,-2',5') causes changes in the performance of the
Na He et al.
Journal of hazardous materials, 164(1), 126-132 (2008-10-01)
Pd/Fe bimetallic particles were synthesized by chemical deposition and used to dechlorinate 2,2',4,5,5'-pentachlorobiphenyl in soil. Batch experiments demonstrated that the Pd/Fe bimetallic particles could effectively dechlorinate 2,2',4,5,5'-pentachlorobiphenyl. Dechlorination was affected by several factors such as reaction time, Pd loading, the

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service