Merck
CN
All Photos(1)

Documents

63184

Sigma-Aldrich

5-Maleimido-eosin

for fluorescence, ≥93% (HPLC)

Sign Into View Organizational & Contract Pricing

Synonym(s):
EMA, Eosin-5-maleimide
Empirical Formula (Hill Notation):
C24H9Br4NO7
CAS Number:
Molecular Weight:
742.95
MDL number:
PubChem Substance ID:
NACRES:
NA.32

grade

for fluorescence

Quality Level

Assay

≥93% (HPLC)

fluorescence

λex 524 nm; λem 545 nm (after derivatization with 2-mercaptoethanol)

storage temp.

2-8°C

SMILES string

Oc1c(Br)cc2c(Oc3c(Br)c(O)c(Br)cc3C24OC(=O)c5cc(ccc45)N6C(=O)C=CC6=O)c1Br

InChI

1S/C24H9Br4NO7/c25-13-6-11-21(17(27)19(13)32)35-22-12(7-14(26)20(33)18(22)28)24(11)10-2-1-8(5-9(10)23(34)36-24)29-15(30)3-4-16(29)31/h1-7,32-33H

InChI key

YRCLWXRIEYQTAV-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

General description

5-Maleimido-eosin, also known as EMA or Eosin-5-maleimide, is a fluorescent binding agent. The 5-Maleimido-eosin binding test measures the EMA-labeled cells reduced mean channel fluorescence (MCF) reading.

Application

Eosin-5-maleimide has been used as a fluorescent probe for the human erythrocyte band 3 protein. It is widely used as a diagnostic probe for the laboratory detection of hereditary spherocytosis (HS) by flow cytometry. The eosin-5-maleimide binding test was done to analyze the effect of alectinib (first line of treatment) for anaplastic lymphoma kinase (ALK).

Other Notes

Triplet probe. Measurement of rotational diffusion of protein in solution and in membranes, including myosin and pyruvate dehydrogenase

related product

Product No.
Description
Pricing

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Personal Protective Equipment

dust mask type N95 (US), Eyeshields, Gloves

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

A J Visser et al.
European journal of biochemistry, 121(1), 233-235 (1981-12-01)
The enzymatically reduced lipoyl residues of the transacetylase component of the pyruvate dehydrogenase complex from Escherichia coli were labeled with eosin maleimide. Using eosin as triplet probe, triplet-triplet absorption dichroism measurements were performed to obtain rotational correlation times of the
Delay in the measurement of eosin-5'-maleimide (EMA) binding does not affect the test result for the diagnosis of hereditary spherocytosis.
Ciepiela O, Kotula I, Gorska E, et al.
Clinical Chemistry and Laboratory Medicine, 0, 1-7 (2012)
P A Knauf et al.
The American journal of physiology, 264(5 Pt 1), C1144-C1154 (1993-05-11)
Eosin-5-maleimide (EM) has been used as a fluorescent probe for the external-facing transport site of the human erythrocyte band 3 protein. Changes in chloride concentration at both sides of the membrane have no significant effect on the inhibitory potency of
Paola Bianchi et al.
Haematologica, 97(4), 516-523 (2011-11-08)
The laboratory diagnosis of hereditary spherocytosis commonly relies on NaCl-based or glycerol-based red cell osmotic fragility tests; more recently, an assay directly targeting the hereditary spherocytosis molecular defect (eosin-5'-maleimide-binding test) has been proposed. None of the available tests identifies all
S Ishiwata et al.
The Journal of biological chemistry, 262(17), 8314-8317 (1987-06-15)
We studied the rotational Brownian motions of myosin heads, of which the sulfhydryl group was selectively labeled with the triplet probe 5-eosinylmaleimide, in myofibril by using flash-induced phosphorescence anisotropy decay measurements. The anisotropy decay curve under relaxing conditions consisted of

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service