Merck
CN
All Photos(1)

Documents

PHR1238

Supelco

Ergocalciferol (Vitamin D2)

Pharmaceutical Secondary Standard; Certified Reference Material

Sign Into View Organizational & Contract Pricing

Synonym(s):
Ergocalciferol, Calciferol, Ercalciol, Ergosterol irradiated, Irradiated ergosterol, Vitamin D2
Empirical Formula (Hill Notation):
C28H44O
CAS Number:
Molecular Weight:
396.65
Beilstein:
1916682
EC Number:
MDL number:
PubChem Substance ID:

grade

certified reference material
pharmaceutical secondary standard

Quality Level

Agency

traceable to BP 788
traceable to Ph. Eur. E0900000
traceable to USP 1239005

API family

ergocalciferol

CofA

current certificate can be downloaded

technique(s)

HPLC: suitable
gas chromatography (GC): suitable

mp

114-118 °C (lit.)

application(s)

clinical testing

format

neat

storage temp.

-10 to -25°C

SMILES string

CC(C)[C@@H](C)/C=C/[C@@H](C)[C@@]1([H])CC[C@@]([C@]1(C)CCC/2)([H])C2=C\C=C(C[C@@H](O)CC3)/C3=C

InChI

1S/C28H44O/c1-19(2)20(3)9-10-22(5)26-15-16-27-23(8-7-17-28(26,27)6)12-13-24-18-25(29)14-11-21(24)4/h9-10,12-13,19-20,22,25-27,29H,4,7-8,11,14-18H2,1-3,5-6H3/b10-9+,23-12+,24-13-/t20-,22+,25-,26+,27-,28+/m0/s1

InChI key

MECHNRXZTMCUDQ-RKHKHRCZSA-N

Gene Information

human ... VDR(7421)

Looking for similar products? Visit Product Comparison Guide

General description

Pharmaceutical secondary standards for application in quality control, provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards.

Application

Ergocalciferol (Vitamin D2) may be used as a pharmaceutical reference standard for the determination of the analyte in serum samples, cosmetics and pharmaceutical formulations by various chromatography techniques.
These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.

Analysis Note

These secondary standards offer multi-traceability to the USP, EP (PhEur) and BP primary standards, where they are available.

Other Notes

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Footnote

To see an example of a Certificate of Analysis for this material enter LRAB7854 in the slot below. This is an example certificate only and may not be the lot that you receive.

Pictograms

Skull and crossbonesHealth hazard

Signal Word

Danger

Hazard Statements

Hazard Classifications

Acute Tox. 2 Inhalation - Acute Tox. 3 Dermal - Acute Tox. 3 Oral - STOT RE 1 Oral

Storage Class Code

6.1A - Combustible, acute toxic Cat. 1 and 2 / very toxic hazardous materials

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Is supercritical fluid chromatography hyphenated to mass spectrometry suitable for the quality control of vitamin D3 oily formulations?
Andri B. et al.
Journal of Chromatography A, 1515(7), 209-217 (2017)
A RAPID METHOD FOR DETERMINATION OF VITAMINS D2 AND D3 IN PHARMACEUTICAL PREPARATIONS BY HPLC
Sarioglu K, et al.
Journal of Liquid Chromatography and Related Technologies, 24(7), 973-982 (2001)
Determination of vitamins A, D, E, and K in human and bovine serum, and ?-carotene and vitamin A palmitate in cosmetic and pharmaceutical products, by isocratic HPLC
Wang LH and Huang SH
Chromatographia, 55(5-6), 289-296 (2002)
Reinhold Vieth
Annals of medicine, 37(4), 278-285 (2005-07-16)
The need for vitamin D to prevent rickets was the drive for selection of lighter skin color in temperate climates. Anthropologists also know that as human populations developed more sedentary lifestyles, this coincided with a decline in bone quantity, quality
R Jorde et al.
European journal of endocrinology, 152(1), 39-45 (2005-03-15)
Smoking is associated with reduced bone density and calcium absorption, and reduced serum levels of vitamin D. A compensatory increase in serum parathyroid hormone (PTH) would therefore be expected as a result of an altered calcium balance. However, reports on

Protocols

This application demonstrates the suitability of the Ascentis Express C18, 5 μm, for the routine analysis of the fat-soluble vitamins D2 and D3 . Structures along with the optimized chromatogram obtained on the Ascentis Express C18, 5 μm are presented.

Separation of Ergocalciferol (D2), analytical standard; Cholecalciferol (D3), analytical standard

Separation of Ergocalciferol (D2), analytical standard; Cholecalciferol (D3), analytical standard

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service