Merck
CN
All Photos(1)

PHR1315

Supelco

Valsartan

Pharmaceutical Secondary Standard; Certified Reference Material

Sign Into View Organizational & Contract Pricing

Select a Size

Change View
Synonym(s):
Valsartan, N-(1-Oxopentyl)-N-[[2′-(2H-tetrazol-5-yl)[1,1′-biphenyl]-4-yl]methyl]-L-valine
Empirical Formula (Hill Notation):
C24H29N5O3
CAS Number:
Molecular Weight:
435.52
MDL number:
PubChem Substance ID:
NACRES:
NA.24

grade

certified reference material
pharmaceutical secondary standard

Quality Level

Agency

traceable to BP 1161
traceable to Ph. Eur. Y0001132
traceable to USP 1708762

API family

valsartan

CofA

current certificate can be downloaded

technique(s)

HPLC: suitable
gas chromatography (GC): suitable

application(s)

pharmaceutical (small molecule)

format

neat

storage temp.

2-8°C

SMILES string

CCCCC(=O)N(Cc1ccc(cc1)-c2ccccc2-c3nnn[nH]3)[C@@H](C(C)C)C(O)=O

InChI

1S/C24H29N5O3/c1-4-5-10-21(30)29(22(16(2)3)24(31)32)15-17-11-13-18(14-12-17)19-8-6-7-9-20(19)23-25-27-28-26-23/h6-9,11-14,16,22H,4-5,10,15H2,1-3H3,(H,31,32)(H,25,26,27,28)/t22-/m0/s1

InChI key

ACWBQPMHZXGDFX-QFIPXVFZSA-N

Gene Information

human ... AGTR1(185)

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
1708762BP1161SML0142
Valsartan Pharmaceutical Secondary Standard; Certified Reference Material

Supelco

PHR1315

Valsartan

Valsartan United States Pharmacopeia (USP) Reference Standard

USP

1708762

Valsartan

Valsartan British Pharmacopoeia (BP) Reference Standard

BP1161

Valsartan

Valsartan ≥98% (HPLC)

Sigma-Aldrich

SML0142

Valsartan

technique(s)

HPLC: suitable, gas chromatography (GC): suitable

technique(s)

-

technique(s)

-

technique(s)

-

application(s)

pharmaceutical (small molecule)

application(s)

pharmaceutical (small molecule)

application(s)

pharmaceutical

application(s)

-

format

neat

format

neat

format

neat

format

-

storage temp.

2-8°C

storage temp.

-

storage temp.

2-8°C

storage temp.

2-8°C

Quality Level

300

Quality Level

-

Quality Level

-

Quality Level

-

General description

Certified pharmaceutical secondary standards for application in quality control provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to pharmacopeia primary standards.
Valsartan is an orally active specific angiotensin II receptor blocker used for the treatment of hypertension.

Application

These Secondary Standards are qualified as Certified Reference Materials. These are suitable for use in several analytical applications including but not limited to pharma release testing, pharma method development for qualitative and quantitative analyses, food and beverage quality control testing, and other calibration requirements.
Valsartan may be used as a pharmaceutical reference standard for the determination of the analyte in pharmaceutical formulations by chromatography and spectrophotometry.

Analysis Note

These secondary standards offer multi-traceability to the USP, EP (PhEur) and BP primary standards, where they are available.

Other Notes

This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.

Footnote

To see an example of a Certificate of Analysis for this material enter LRAC2970 in the slot below. This is an example certificate only and may not be the lot that you receive.

Pictograms

Exclamation markHealth hazard

Signal Word

Warning

Hazard Statements

Precautionary Statements

Hazard Classifications

Repr. 2 - STOT SE 3

Target Organs

Central nervous system

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 8

1 of 8

Valsartan Related Compound A United States Pharmacopeia (USP) Reference Standard

USP

1708773

Valsartan Related Compound A

LBQ657 ≥97% (HPLC)

Sigma-Aldrich

SML2064

LBQ657

Telmisartan Pharmaceutical Secondary Standard; Certified Reference Material

Supelco

PHR1855

Telmisartan

Losartan Potassium Pharmaceutical Secondary Standard; Certified Reference Material

Supelco

PHR1602

Losartan Potassium

Candesartan Cilexetil Pharmaceutical Secondary Standard; Certified Reference Material

Supelco

PHR1854

Candesartan Cilexetil

Stability indicating RP-HPLC method for determination of valsartan in pure and pharmaceutical formulation
Patro SK, et al.
Journal of Chemistry, 7(1), 246-252 (2010)
Stability-indicating UPLC method for determination of Valsartan and their degradation products in active pharmaceutical ingredient and pharmaceutical dosage forms
Krishnaiah Ch, et al.
Journal of Pharmaceutical and Biomedical Analysis, 53(3), 483-489 (2010)
Simultaneous spectrophotometric determination of valsartan and ezetimibe in pharmaceuticals
Ramachandran S, et al.
Tropical Journal of Pharmaceutical Research, 10(6), 809-815 (2011)
Simultaneous determination of valsartan and hydrochlorothiazide in tablets by RP-HPLC
Tian FD, et al.
Indian Journal of Pharmaceutical Sciences, 70(3), 372-372 (2008)
Roberto Fogari et al.
Expert opinion on drug safety, 10(2), 295-303 (2010-12-15)
Angiotensin receptor blockers (ARBs) as a class are generally considered safe and better tolerated than other antihypertensive drugs. The purpose of this report is to review the main data on the safety and tolerability of the second generation ARB valsartan

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service