ligand
recombinant protein G lacking albumin-binding region
packaging
pkg of 1 kit
manufacturer/tradename
Cytiva 17-1128-01
storage condition
(20% Ethanol)
parameter
<4 mL/min flow rate
42 psi
bed size
7 mm × 25 mm
bed volume
1 mL
column I.D.
7 mm
matrix
highly cross-linked 6% agarose
avg. part. size
34 μm
cleaning
2-9
working range
3-9
capacity
>1 mg binding capacity (lgG/column)
storage temp.
2-8°C
General description
MAbTrap® is an affinity chromatography kit, with everything required for small-scale IgG purification from ascites fluid, serum, and cell culture supernatants.
The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.
pH below 3 is sometimes required to elute strongly bound IgG species. However, protein ligands may hydrolyze at very low pH.
Application
MAbTrap® Kit is an affinity chromatography kit for fast and effective purification of monoclonal and polyclonal IgG from ascites fluid, serum, and cell culture supernatants. MAbTrap® Kit contains everything necessary to perform a complete one step purification without using complicated equipment. It also eliminates time-consuming buffer preparation and column packing. The kit includes one HiTrap® column, prepacked with Protein G Sepharose™ High Performance.
Features and Benefits
- Convenient kit for purification of IgG from monoclonal and polyclonal material using a syringe in less than 15 min.
- Kit contains one HiTrap® Protein G HP column prepacked with Protein G Sepharose™ High Performance and enough buffer concentrate for 20 preparations with a syringe.
- MAbTrap® Kit contains everything necessary to perform a complete one-step purification without using complex equipment.
Preparation Note
Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Analysis Note
To view the Certificate of Analysis for this product, please visit www.cytiva.com.
Other Notes
The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.
Legal Information
HiTrap is a registered trademark of Cytiva
MAbTrap is a registered trademark of Cytiva
Sepharose is a trademark of Cytiva
Signal Word
Warning
Hazard Statements
Precautionary Statements
Storage Class Code
3 - Flammable liquids
Choose from one of the most recent versions:
Certificates of Analysis (COA)
Lot/Batch Number
It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.
If you need assistance, please contact Customer Support
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service