GE17-5111-01

HiTrap® IGY Purification

Cytiva 17-5111-01, pack of 1 × 5 mL

别名:

IgY purification column, affinity column, chromatography column, egg yolk chromatography column, prepacked column, protein G column

登录 查看组织和合同定价。

选择规格

变更视图

关于此项目

NACRES:
NA.56
UNSPSC Code:
23151816
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


ligand

2-mercaptopyridine

packaging

pack of 1 × 5 mL

manufacturer/tradename

Cytiva 17-5111-01

storage condition

(20% Ethanol)

parameter

<20 mL/min flow rate, 42 psi

bed size

16 mm × 25 mm

bed volume

5 mL

column I.D.

16 mm

matrix

highly cross-linked 6% agarose

avg. part. size

34 μm

cleaning

2-13

working range

3-11

storage temp.

2-30°C

General description

HiTrap® IgY Purification HP is a 5 mL column prepacked with Sepharose High Performance for fast and easy purification of IgY from egg yolk.

Application

HiTrap® IgY Purification HP is packed with a thiophilic adsorption medium, 2-merCaptopyridine coupled to Sepharose High Performance. Thiophilic adsorption is promoted by water-structuring salts. It has been suggested that the interaction of IgY and ligand results from combined electron donating and accepting action of the ligand or, alternatively, a mixed mode hydrophilic-hydrophobic interaction.

Features and Benefits

  • Each column binds IgY from a one-quarter portion of egg yolk (approx. 100 mg IgY). For greater capacity, several columns may be connected in series.
  • Packed with a thiophilic adsorption medium, the ligand, 2-merCaptopyridine is coupled to Sepharose High Performance.
  • Recovery and purity of IgY are excellent.
  • Can be operated with a liquid chromatography system such as ÄKTA® design.
  • The top and bottom frits are manufactured from porous polyethylene
  • Connectors for usage with different chromatography systems and other equipment are included

Preparation Note

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

Analysis Note

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Other Notes

The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.

Legal Information

HiTrap is a registered trademark of Cytiva
Sepharose is a trademark of Cytiva
ÄKTA is a registered trademark of Cytiva


pictograms

Flame

signalword

Warning

hcodes

存储类别

3 - Flammable liquids



历史批次信息供参考: