Merck
CN
All Photos(1)

Documents

10357

Supelco

Amberlite XAD®-2

pkg of 500 g

Sign Into View Organizational & Contract Pricing

CAS Number:

form

beads (small)

Quality Level

packaging

pkg of 500 g

availability

not available in (Currently experiencing backorder delays due to raw material supply disruption)

technique(s)

HPLC: suitable
LPLC: suitable

surface area

~300 m2/g

matrix

styrene-divinylbenzene (macroreticular)

matrix active group

polymer

particle size

20-60 mesh

pore size

~0.65 mL/g pore volume
90 Å mean pore size

density

1.02 g/mL at 25 °C (true wet)(lit.)
1.08 g/mL at 25 °C (skeletal)(lit.)

separation technique

reversed phase

storage temp.

2-8°C

InChI

1S/C24H27NO5/c1-24(2,3)30-22(27)13-12-16(14-26)25-23(28)29-15-21-19-10-6-4-8-17(19)18-9-5-7-11-20(18)21/h4-11,14,16,21H,12-13,15H2,1-3H3,(H,25,28)/t16-/m0/s1

InChI key

BCIPGSZQUDLGSY-INIZCTEOSA-N

Looking for similar products? Visit Product Comparison Guide

Related Categories

General description

Amberlite XAD-2, a hydrophobic copolymer of styrene-divinylbenzene resin, requires longer purification process and is used as a sorbent. Amberlite XAD-2 resin depending upon the aromaticity and size of the hydrophobic groups sorbs organic compounds through low-energy physical interactions.
Nonionic macroreticular resin that adsorbs and releases ionic species through hydrophobic and polar interactions; usually used under isocratic conditions.
Specifications:

Application

Amberlite XAD®-2 was used:
  • as adsorbent in the extraction of organochlorine compounds using Soxhlat extraction technique
  • as adsorbent in the extraction of honey samples using column chromatography for HPLC analysis
  • in adsorption chromatography
Polyaromatic adsorbent resin for hydrophobic compounds up to MW 20,000: phenols, organic removal, surfactants, aroma compounds, antibiotic recovery. May be used as support for catalyst or metals removal. For cleaned US EPA versions, see Supelpak-2 and Supelpak-2B.
     

Legal Information

Amberlite is a trademark of DuPont de Nemours, Inc.
XAD is a registered trademark of The Dow Chemical Company or an affiliated company of Dow

related product

Product No.
Description
Pricing

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Personal Protective Equipment

dust mask type N95 (US), Eyeshields, Gloves

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

  1. Which document(s) contains shelf-life or expiration date information for a given product?

    If available for a given product, the recommended re-test date or the expiration date can be found on the Certificate of Analysis.

  2. How do I get lot-specific information or a Certificate of Analysis?

    The lot specific COA document can be found by entering the lot number above under the "Documents" section.

  3. Is Amberlite XAD-2 ready-to-use?

    No.  Amberlite XAD2 is shipped imbibed with 5% NaCl & 1% NaCO3; it has not been specially processed nor cleaned. We suggest that it be extensively treated to a suitable preliminary elution and wash.

  4. Do you offer a precleaned Amberlite XAD-2?

    Yes.  Supelco cleans Amberlite XAD2 for a variety of environmental applications.

  5. May I purchase Amberlite XAD-2 in large quantities?

    The largest package size of Amberlite XAD2 is 25 kg (Product No. 3025-U).

  6. How do I find price and availability?

    There are several ways to find pricing and availability for our products. Once you log onto our website, you will find the price and availability displayed on the product detail page. You can contact any of our Customer Sales and Service offices to receive a quote.  USA customers:  1-800-325-3010 or view local office numbers.

  7. What is the Department of Transportation shipping information for this product?

    Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product. 

  8. My question is not addressed here, how can I contact Technical Service for assistance?

    Ask a Scientist here.

Trapping efficiency of polyurethane foam and Amberlite XAD-2 for various organochlorine compounds
Nerin, C., et al.
Fresenius Journal of Analytical Chemistry, 352, 609-611 (1995)
I Martos et al.
Journal of agricultural and food chemistry, 48(5), 1498-1502 (2000-05-23)
European Eucalyptus honeys showed a common and characteristic HPLC profile in which the flavonoids myricetin (3,5,7,3',4', 5'-hexahydroxyflavone), tricetin (5,7,3',4',5'-pentahydroxyflavone), quercetin (3,5,7,3',4'-pentahydroxyflavone), luteolin (5,7,3', 4'-tetrahydroxyflavone), and kaempferol (3,5,7, 4'-tetrahydroxyflavone) were identified. Their contents, and relative amounts, in the analyzed honey samples
Tim J Causon et al.
Journal of chromatography. A, 1217(21), 3519-3524 (2010-04-21)
Alternative approaches to conventional acetonitrile gradient methods for reversed-phase liquid chromatographic analysis of intact proteins have been investigated using commercial poly(styrene-co-divinylbenzene) monolithic columns (Dionex ProSwift RP-2H and RP-4H). Alternative solvents to acetonitrile (2-propanol and methanol) coupled with elevated temperatures demonstrated
Mario Vincenzo Russo et al.
Analytical and bioanalytical chemistry, 404(5), 1517-1527 (2012-07-05)
This paper shows an analytical methodology based on solid-phase extraction by XAD-2 adsorbent and gas chromatography (GC) coupled with nitrogen-phosphorus (NPD) and ion-trap mass spectrometry detectors (ITMS) in negative chemical ionization (NCI) mode analyses for investigating organophosphorus pesticides (OPs) at
Feng Xiao et al.
Journal of colloid and interface science, 368(1), 505-511 (2011-12-14)
Amberlite XAD resins have been employed to a great extent as the sorbent for removing or concentrating organic compounds from different matrices. We present for the first time a systematic study on the sorption of perfluorochemical (PFC) surfactants, an emerging

Related Content

Low pressure liquid chromatography (LPLC) operates at low pressures, using a pump to drive the mobile phase onto the column.

FAS, or 'forever chemicals,' persist in the environment and pose risks to human health. Discover our environmental monitoring tools for PFAS quantification, aiding researchers, regulators, and labs in testing for PFAS.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service