跳转至内容
Merck
CN

117323

4,4′-亚甲基双(2-氯苯胺)

85%

别名:

2,2′-二氯-4,4′-亚甲基二苯胺, 4,4′-二氨基-3,3′-二氯二苯甲烷

登录 查看公司和协议定价

选择尺寸


关于此项目

线性分子式:
CH2[C6H3(Cl)NH2]2
化学文摘社编号:
分子量:
267.15
Beilstein:
1882318
EC 号:
MDL编号:
UNSPSC代码:
12162002
PubChem化学物质编号:
NACRES:
NA.23
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

方案

85%

表单

solid

沸点

202-214 °C/0.3 mmHg (lit.)

mp

102-107 °C (lit.)

SMILES字符串

Nc1ccc(Cc2ccc(N)c(Cl)c2)cc1Cl

InChI

1S/C13H12Cl2N2/c14-10-6-8(1-3-12(10)16)5-9-2-4-13(17)11(15)7-9/h1-4,6-7H,5,16-17H2

InChI key

IBOFVQJTBBUKMU-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

警示用语:

Danger

危险分类

Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 1 - Carc. 1B - Muta. 2

储存分类代码

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

WGK 3

闪点(°F)

235.4 °F - closed cup

闪点(°C)

113 °C - closed cup

法规信息

危险化学品
此项目有

历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Evaluation of worker exposure to TDI, MOCA, and methylene chloride.
Richard Fairfax et al.
Journal of occupational and environmental hygiene, 3(6), D50-D53 (2006-04-20)
T M Reid et al.
Toxicology letters, 95(3), 205-210 (1998-08-15)
The genotoxic potential of two occupationally significant chemicals, 4,4'-methylene-bis-2-chloroaniline (MOCA) and 2-phenyl-1,4-benzoquinone (PBQ), was explored by monitoring the induction of mutations at the HPRT locus of AHH-1 human lymphoblastoid cells. Exposure of AHH-1 cells to the putative carcinogenic metabolite of
P Vineis et al.
Cancer causes & control : CCC, 8(3), 346-355 (1997-05-01)
Epidemiological evidence on the relation between aromatic amines and cancer risk is reviewed. In particular, cancer risk in humans resulting from exposure to aromatic amines from occupational sources and tobacco smoking is assessed with reference to ecologic, cohort, and case-control
A Jeżewska et al.
Toxicology mechanisms and methods, 21(7), 554-560 (2011-04-09)
A new procedure has been developed for the assay of 2,2'-dichloro-4,4'-methylenedianiline (MOCA) using high-performance liquid chromatography with diode array detector. MOCA was sampled from workplace air and derivative before determination using 3,5-dinitrobenzoyl chloride. The determination was carried out in the
Hong-I Chen et al.
Urology, 66(2), 305-310 (2005-08-16)
Transitional cell carcinoma of the urinary bladder is associated with occupational exposure to 4,4'-methylenebis(2-chloroaniline) (MBOCA). A program to monitor MBOCA levels in the work environment and to screen for bladder cancer was performed at four MBOCA manufacturing factories. The U.S.

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持