登录 查看组织和合同定价。
选择尺寸
关于此项目
线性分子式:
CH3CN
化学文摘社编号:
分子量:
41.05
UNSPSC Code:
12190000
PubChem Substance ID:
EC Number:
200-835-2
Beilstein/REAXYS Number:
741857
MDL number:
Assay:
≥99.93%
Grade:
HPLC grade
Technique(s):
HPLC: suitable
Vapor pressure:
72.8 mmHg ( 20 °C)
产品名称
乙腈, HPLC grade, ≥99.93%
grade
HPLC grade
vapor pressure
72.8 mmHg ( 20 °C)
description
gradient analysis <= 0.005 254nm
assay
≥99.93%
form
liquid
autoignition temp.
973 °F
purified by
sub-micron filtration
technique(s)
HPLC: suitable
impurities
<0.005% water
evapn. residue
<0.0002%
color
colorless
mp
−45 °C (lit.), −48 °C
solubility
water: soluble (completely)
absorption
<0.005 mAU at 254 nm
λ
H2O reference
UV absorption
λ: 190 nm Amax: 1.00, λ: 200 nm Amax: 0.05, λ: 210 nm Amax: 0.03, λ: 220 nm Amax: 0.01, λ: 235-400 nm Amax: 0.005
format
neat
正在寻找类似产品? 访问 产品对比指南
signalword
Danger
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
存储类别
3 - Flammable liquids
wgk
WGK 2
flash_point_f
35.6 °F - closed cup
flash_point_c
2.0 °C - closed cup
ppe
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
法规信息
新产品
此项目有
Michelangelo Anastassiades et al.
Journal of AOAC International, 86(2), 412-431 (2003-05-02)
A simple, fast, and inexpensive method for the determination of pesticide residues in fruits and vegetables is introduced. The procedure involves initial single-phase extraction of 10 g sample with 10 mL acetonitrile, followed by liquid-liquid partitioning formed by addition of
Purification of acetonitrile.
Walter M and Ramaley L.
Analytical Chemistry, 45(1), 165-166 (1973)
Timo Glatter et al.
Molecular systems biology, 5, 237-237 (2009-01-22)
Protein complexes represent major functional units for the execution of biological processes. Systematic affinity purification coupled with mass spectrometry (AP-MS) yielded a wealth of information on the compendium of protein complexes expressed in Saccharomyces cerevisiae. However, global AP-MS analysis of
Kangmin Chon et al.
Water research, 81, 388-397 (2015-07-05)
In this study, the changes in UV absorbance at 254 nm (UVA254) and electron donating capacity (EDC) were investigated as surrogate indicators for assessing removal of micropollutants and bromate formation during ozonation of wastewater effluents. To measure the EDC, a novel
Elke H J Krekels et al.
Clinical pharmacokinetics, 53(6), 553-563 (2014-02-06)
From a previously validated paediatric population pharmacokinetic model, it was derived that non-linear morphine maintenance doses of 5 μg/kg(1.5)/h, with a 50 % dose reduction in neonates with a postnatal age (PNA) <10 days, yield similar morphine and metabolite concentrations
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.