跳转至内容
Merck
CN

378836

氟化镁

random crystals, ≥99.99% trace metals basis

别名:

氟化镁

登录 查看组织和合同定价。

选择尺寸


关于此项目

线性分子式:
MgF2
化学文摘社编号:
分子量:
62.30
NACRES:
NA.23
PubChem Substance ID:
UNSPSC Code:
12352302
EC Number:
231-995-1
MDL number:
Assay:
≥99.99% trace metals basis
Form:
random crystals
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

InChI key

ORUIBWPALBXDOA-UHFFFAOYSA-L

InChI

1S/2FH.Mg/h2*1H;/q;;+2/p-2

SMILES string

F[Mg]F

assay

≥99.99% trace metals basis

form

random crystals

reaction suitability

core: magnesium

impurities

≤100.0 ppm Trace Metal Analysis

density

3.15 g/mL at 25 °C (lit.)

Quality Level

正在寻找类似产品? 访问 产品对比指南

Application

  • 采用氟化镁和氟化镁-磷酸镁双层涂层控制镁的降解速率:该研究讨论了控制镁降解速率的涂层,该涂层可能对生物医学应用(如可生物吸收植入物)很关键 (K Ravichandran, SN TSN, 2022)。
  • 基于氟化镁的无需电成型的双极电阻式开关存储器:讨论了采用氟化镁的电阻式开关存储设备的开发,重点关注了其在非易失性存储技术中的应用(NC Das et al., 2021)。
  • 采用氟化镁光子晶体光纤(photonic crystal fiber)进行光学相干断层扫描的超连续谱生成探索了氟化镁在光子晶体光纤中改善超连续谱生成的用途,这对光学相干断层扫描技术很关键 (A Ghanbari et al., 2017)。

pictograms

Exclamation mark

signalword

Warning

hcodes

Hazard Classifications

STOT SE 3

target_organs

Respiratory system

存储类别

13 - Non Combustible Solids

wgk

WGK 1

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

dust mask type N95 (US), Eyeshields, Gloves


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

J Preben Morth et al.
Nature, 450(7172), 1043-1049 (2007-12-14)
The Na+,K+-ATPase generates electrochemical gradients for sodium and potassium that are vital to animal cells, exchanging three sodium ions for two potassium ions across the plasma membrane during each cycle of ATP hydrolysis. Here we present the X-ray crystal structure
Jonathan Lellouche et al.
International journal of nanomedicine, 7, 1175-1188 (2012-03-16)
The ability of bacteria to colonize catheters is a major cause of infection. In the current study, catheters were surface-modified with MgF(2) nanoparticles (NPs) using a sonochemical synthesis protocol described previously. The one-step synthesis and coating procedure yielded a homogenous
Tobias Bocksrocker et al.
Optics express, 20(6), 6170-6174 (2012-03-16)
We report a simple approach to enhance the out-coupling efficiency in white organic light emitting diodes (WOLEDs). By incorporating MgF₂-columns into the ITO-anode and optimizing of their geometry, an overall efficiency enhancement of up to 38% is achieved. In addition
Martina Thomann et al.
Journal of biomedical materials research. Part A, 93(4), 1609-1619 (2010-01-15)
MgCa0.8 cylinders (2.5 x 25 mm(2)) were coated with a magnesium-fluoride layer and implanted in the marrow cavities of both tibiae of 10 New Zealand White rabbits. The implantation duration was 3 and 6 months. The implants were clinically well
Jonathan Lellouche et al.
Biomaterials, 30(30), 5969-5978 (2009-08-12)
The ability of bacteria to develop antibiotic resistance and colonize abiotic surfaces by forming biofilms is a major cause of medical implant-associated infections and results in prolonged hospitalization periods and patient mortality. This raises the urgent need to develop compounds

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持