439533
2,4,6-三溴-3-羟基苯甲酸
97%
别名:
3-羟基-2,4,6-三溴苯甲酸
登录查看公司和协议定价
关于此项目
线性分子式:
HC6Br3(OH)CO2H
CAS Number:
分子量:
374.81
MDL编号:
UNSPSC代码:
12352100
PubChem化学物质编号:
NACRES:
NA.22
质量水平
方案
97%
表单
powder
mp
145-148 °C (lit.)
官能团
bromo
carboxylic acid
SMILES字符串
OC(=O)c1c(Br)cc(Br)c(O)c1Br
InChI
1S/C7H3Br3O3/c8-2-1-3(9)6(11)5(10)4(2)7(12)13/h1,11H,(H,12,13)
InChI key
YDBHVMTTYXWHLI-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
一般描述
2,4,6-三溴-3-羟基苯甲酸(TBHBA)是一种用作结构单元的有机化合物。TBHBA 是一种测定血浆中高密度脂蛋白(HDL)游离胆固醇部分的酶比色试剂。
应用
- 一锅合成法和纳米生物应用:研究描述了一种利用2,4,6-三溴-3-羟基苯甲酸一锅自下而上合成2D石墨烯衍生物的技术,展示了其在生物分子识别和纳米酶活性方面的应用(Pandit and De, 2021)。
警示用语:
Warning
危险分类
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
靶器官
Respiratory system
储存分类代码
11 - Combustible Solids
WGK
WGK 3
个人防护装备
dust mask type N95 (US), Eyeshields, Gloves
J S Moshides
Scandinavian journal of clinical and laboratory investigation, 48(1), 59-64 (1988-02-01)
A sensitive enzymatic method for the measurement of high density lipoprotein choline-containing phospholipids (HDL-pc) was adapted to a Cobas Bio Centrifugal Analyzer. The Boehringer Mannheim phospholipase D/choline oxidase/peroxidase reagent was modified by the inclusion of 2,4,6,-tribromo-3-hydroxybenzoic acid (TBHBA) which reacts
V Saroja Voruganti et al.
The American journal of clinical nutrition, 101(4), 725-732 (2015-04-04)
Elevated concentrations of serum uric acid are associated with increased risk of gout and renal and cardiovascular diseases. Genetic studies in adults have consistently identified associations of solute carrier family 2, member 9 (SLC2A9), polymorphisms with variation in serum uric
One-pot bottom-up synthesis of a 2D graphene derivative: Application in biomolecular recognition and nanozyme activity
Pandit S, et al.
Nanoscale advances, 3(17), 5102-5110 (2021)
P Trinder et al.
Annals of clinical biochemistry, 21 ( Pt 5), 430-433 (1984-09-01)
The Boehringer one-component high-performance cholesterol oxidase reagent has been modified by the inclusion of 2,4,6-tribromo-3-hydroxybenzoic acid (TBHBA) to give a fourfold increase in sensitivity to a molar absorbance of approximately equal to 29,000 with respect to cholesterol. The resulting reagent
J S Moshides
Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie, 25(9), 583-587 (1987-09-01)
A sensitive fixed-time kinetic enzymatic method for the measurement of high density lipoprotein cholesterol is described, as adapted for the Cobas Bio centrifugal analyser (Hoffmann LaRoche). The Boehringer Mannheim cholesterol esterase/cholesterol oxidase/peroxidase/3,4-dichlorophenol kinetic reagent was modified by the inclusion of
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持