登录 查看组织和合同定价。
选择尺寸
关于此项目
线性分子式:
[CH3(CH2)7]3P
化学文摘社编号:
分子量:
370.64
NACRES:
NA.22
PubChem Substance ID:
UNSPSC Code:
12352001
EC Number:
225-234-2
MDL number:
Beilstein/REAXYS Number:
1776995
产品名称
三正辛基膦, 97%
InChI
1S/C24H51P/c1-4-7-10-13-16-19-22-25(23-20-17-14-11-8-5-2)24-21-18-15-12-9-6-3/h4-24H2,1-3H3
InChI key
RMZAYIKUYWXQPB-UHFFFAOYSA-N
SMILES string
CCCCCCCCP(CCCCCCCC)CCCCCCCC
assay
97%
form
liquid
reaction suitability
reaction type: Buchwald-Hartwig Cross Coupling Reaction
reaction type: Heck Reaction
reaction type: Hiyama Coupling
reaction type: Negishi Coupling
reaction type: Sonogashira Coupling
reaction type: Stille Coupling
reaction type: Suzuki-Miyaura Coupling
reagent type: ligand
refractive index
n20/D 1.468 (lit.)
bp
284-291 °C/50 mmHg (lit.)
density
0.831 g/mL at 25 °C (lit.)
functional group
phosphine
Quality Level
正在寻找类似产品? 访问 产品对比指南
Application
三辛基膦可用于金属纳米晶、块状粉体、箔、线、薄膜向金属磷化物的转化。它还可以作为由醋酸镉和硫中合成硫化镉纳米棒反应的溶剂和稳定剂。
General description
三辛基膦可作为磷源,用于金属纳米颗粒的合成。
signalword
Danger
hcodes
Hazard Classifications
Eye Dam. 1 - Skin Corr. 1B
存储类别
8A - Combustible corrosive hazardous materials
wgk
WGK 2
flash_point_f
296.6 °F - closed cup
flash_point_c
147 °C - closed cup
Trioctylphosphine as both solvent and stabilizer to synthesize CdS nanorods.
Chen S, et al.
Nanoscale Research Letters, 4(10), 1159-1159 (2009)
Trioctylphosphine: a general phosphorus source for the low-temperature conversion of metals into metal phosphides.
Henkes AE & Schaak RE.
Chemistry of Materials, 19(17), 4234-4242 (2007)
Palladium (ii)-complexes of bi-and tri-dentate phosphine ligands: precursor for palladium--phosphorous nanoparticles and activity towards Suzuki--Miyaura coupling
Rao GK, et al.
New. J. Chem., 47, 4218-4227 (2023)
Jaehoon Lim et al.
Nature materials, 17(1), 42-49 (2017-11-29)
Chemically synthesized semiconductor quantum dots (QDs) can potentially enable solution-processable laser diodes with a wide range of operational wavelengths, yet demonstrations of lasing from the QDs are still at the laboratory stage. An important challenge-realization of lasing with electrical injection-remains
Tilman Läppchen et al.
EJNMMI physics, 7(1), 22-22 (2020-04-24)
For multicenter clinical studies, PET/CT and SPECT/CT scanners need to be validated to ensure comparability between various scanner types and brands. This validation is usually performed using hollow phantoms filled with radioactive liquids. In recent years, 3D printing technology has
相关内容
Phosphine Ligand Application Guide
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持