1.00012

丙酮

for gas chromatography ECD and FID SupraSolv®

别名:

Dimethyl ketone, Propanone, 2-Propanone

登录并加购,请在购物车里查看协议价、货期和发货地。

选择规格

变更视图

关于此项目

线性分子式:
CH3COCH3
化学文摘社编号:
分子量:
58.08
UNSPSC Code:
12191502
NACRES:
NA.03
EC Index Number:
200-662-2
MDL number:
Beilstein/REAXYS Number:
635680
Assay:
≥99.8% (GC)
Technique(s):
gas chromatography (GC): suitable
Bp:
56 °C/760 mmHg (lit.)
Vapor pressure:
184 mmHg ( 20 °C)
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


Quality Segment

vapor density

2 (vs air)

vapor pressure

184 mmHg ( 20 °C)

product line

SupraSolv®

assay

≥99.8% (GC)

form

liquid

autoignition temp.

465 °C (DIN 51794)

potency

5800 mg/kg LD50, oral (Rat), 20000 mg/kg LD50, skin (Rabbit)

expl. lim.

13.2 %

technique(s)

gas chromatography (GC): suitable

impurities

≤0.05% Water

evapn. residue

≤3.0 mg/L

color

APHA: ≤10

refractive index

n20/D 1.359 (lit.)

pH

5-6 (20 °C, 395 g/L in H2O)

capacity

1000  g/kg water absorbing capacity

bp

56 °C/760 mmHg (lit.)

mp

−94 °C (lit.)

transition temp

flash point <-20 °C

density

0.791 g/mL at 25 °C (lit.)

format

neat

storage temp.

2-30°C

SMILES string

CC(C)=O

InChI

1S/C3H6O/c1-3(2)4/h1-2H3

InChI key

CSCPPACGZOOCGX-UHFFFAOYSA-N

General description

SupraSolv® ECD and FID is a high-purity solvent grade specifically formulated for sample preparation in gas chromatography with electron capture (ECD) and flame ionization (FID) detection.ECD and FID impose distinct and stringent solvent purity requirements. The electron capture detector is exquisitely sensitive to electronegative species — particularly halogenated compounds — at sub-nanogram concentrations, while the flame ionization detector responds to any carbon-containing organic impurity undergoing combustion. SupraSolv® ECD and FID solvents are therefore subjected to rigorous purification and detector-specific testing protocols to ensure that intrinsic solvent impurities remain below the respective detection thresholds of both detector types simultaneously.

Application

These solvents are routinely employed in PCB and organochlorine determination in water and soil, pesticide residue analysis in food and environmental matrices, dioxin screening, and hydrocarbon index measurements — applications where detector sensitivity demands the highest attainable solvent purity to ensure method selectivity and regulatory compliance.
丙酮的发光强度取决于溶液组分。丙酮吸收UV光,导致丙酮光分解和放射性产物。

Features and Benefits

• Dual-detector validation for both ECD and FID within a single solvent grade
• Detector-specific impurity control, targeting the precise analyte classes most detrimental to ECD (halogenated compounds) and FID (hydrocarbons and organic residues) performance, resp.
• Widest specified retention time range, guaranteeing a clean chromatographic baseline from early- to late-eluting analytes
• Batch-to-batch consistency, ensuring long-term reproducibility across routine and regulatory analytical workflows

Analysis Note

SupraSolv® ECD and FID solvents are tested and certified against stringent detector-specific purity thresholds across defined chromatographic retention time windows, including:
  • GC-ECD (early retention window): ≤ 1 ng/mL relative to tetrachloromethane
  • GC-ECD (late retention window): ≤ 2 pg/mL relative to lindane
  • GC-FID: ≤ 2 ng/mL relative to n-tetradecane

Other Notes

欢迎探索各式各样的实验室安全配件和设备,以安全操作溶剂,在首次使用时就能获得较高的安全水平。

Legal Information

SUPRASOLV is a registered trademark of Merck KGaA, Darmstadt, Germany


Still not finding the right product?

Explore all of our products under 丙酮


pictograms

FlameExclamation mark

signalword

Danger

Hazard Classifications

Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 3

target_organs

Respiratory system

supp_hazards

存储类别

3 - Flammable liquids

wgk

WGK 1

flash_point_f

1.4 °F - closed cup

flash_point_c

-17.0 °C - closed cup