登录并加购,请在购物车里查看协议价、货期和发货地。
选择规格
变更视图
关于此项目
线性分子式:
CH2Cl2
化学文摘社编号:
分子量:
84.93
UNSPSC Code:
12191502
NACRES:
NA.03
EC Index Number:
200-838-9
MDL number:
Beilstein/REAXYS Number:
1730800
Assay:
≥99.9% (GC)
Technique(s):
GC/MS: suitable, gas chromatography (GC): suitable
Bp:
39.8-40 °C (lit.)
Vapor pressure:
24.45 psi ( 55 °C), 6.83 psi ( 20 °C)
vapor density
2.9 (vs air)
Quality Segment
vapor pressure
24.45 psi ( 55 °C), 6.83 psi ( 20 °C)
product line
SupraSolv®
assay
≥99.9% (GC)
form
liquid
autoignition temp.
1223 °F, 605 °C (DIN 51794)
potency
1600 mg/kg LD50, oral (Rat), >2000 mg/kg LD50, skin (Rat)
contains
2-Methyl-2-butene as stabilizer
expl. lim.
22 %
technique(s)
GC/MS: suitable, gas chromatography (GC): suitable
impurities
≤0.005% Water
evapn. residue
≤3.0 mg/L
color
APHA: ≤10
refractive index
n
pH
7 (20 °C)
bp
39.8-40 °C (lit.)
mp
-95 °C, −95 °C (lit.)
solubility
20 g/L
density
1.325 g/mL at 25 °C (lit.)
suitability
suitable for residue analysis
storage temp.
2-30°C
SMILES string
ClCCl
InChI
1S/CH2Cl2/c2-1-3/h1H2
InChI key
YMWUJEATGCHHMB-UHFFFAOYSA-N
General description
SupraSolv® hypergrade is a premium-purity solvent grade specifically engineered for organic trace analysis in gas chromatography (GC), where ultra-low background interference and maximum signal-to-noise ratio are paramount analytical requirements.
Application
SupraSolv® hypergrade solvents are indispensable in highly sensitive GC-based applications including pesticide residue analysis, dioxin and polychlorinated biphenyl (PCB) determination, mineral oil index measurements, environmental monitoring, and food safety testing — analytical domains where solvent purity directly governs method reliability and regulatory compliance.
Features and Benefits
- Universal detector compatibility, eliminating the need for detector-specific solvent selection and simplifying laboratory workflows
- Extended and broader specified retention time range, enabling reliable detection of both low- and high-boiling analytes within a single analytical run
- Batch-to-batch consistency and rigorous lot-specific quality control, ensuring reproducibility across analytical series
- Minimized matrix-induced interferences, critical for achieving accurate quantification at ppt to ppb concentration levels
Analysis Note
The hypergrade designation reflects adherence to exceptionally stringent analytical thresholds, including
- ≤ 1 ng/mL interfering impurities relative to tetrachloromethane by GC-ECD
- ≤ 2 pg/mL for lindane equivalents by GC-ECD
- ≤ 2 ng/mL for n-tetradecane equivalents by GC-FID and GC-MSThese specifications ensure that solvent-derived background signals remain below the detection threshold of the most sensitive analytical methods, thereby safeguarding the integrity of trace-level quantification.
Other Notes
Explore various lab safety accessories and equipment for safe handling of solvents to increase your safety level from the first usage.
Legal Information
SUPRASOLV is a registered trademark of Merck KGaA, Darmstadt, Germany
Still not finding the right product?
Explore all of our products under 二氯甲烷
signalword
Warning
hcodes
Hazard Classifications
Carc. 2 - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
target_organs
Central nervous system
存储类别
6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects
wgk
WGK 2