跳转至内容
Merck
CN

1.14761

Iron Test, photometric

photometric, 0.0025-5.00 mg/L (Fe), Spectroquant®

登录 查看组织和合同定价。

选择尺寸

变更视图

关于此项目

UNSPSC Code:
41116116
NACRES:
NA.24
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


产品名称

铁测试, photometric, 0.0025-5.00 mg/L (Fe), Spectroquant®

product line

Spectroquant®

Quality Level

usage

sufficient for 1000 tests, sufficient for 250 tests (depending on package size)

specific analyte(s)

iron

measuring range

0.0025-5.00 mg/L (Fe)

technique(s)

photometry: suitable

application(s)

agriculture
aquaculture
boiler and cooling water
construction materials
disposal drainage water
drinking water
electroplating
environmental
food testing
ground and surface water
mineral water
mining
power plants
seawater
swimming pools
wastewater

compatibility

for use with Spectroquant® Move 100, for use with Spectroquant® Nova 60 A, for use with Spectroquant® Prove 100 (plus), for use with Spectroquant® Prove 300 (plus), for use with Spectroquant® Prove 600 (plus)

detection method

photometric (Triazine)

storage temp.

15-25°C

General description

方法:光度法0.0025 - 5.00 mg/l Fe Spectroquant®
该Spectroquant
® 铁测试可以准确定量各种水中的铁离子。所有铁离子都被还原为二价铁离子。在巯基乙酸盐缓冲介质中,这些物质与三嗪衍生物反应形成一种可用光度法测定的红紫色络合物。
MQuant® 试纸非常适合以经济、快速的方式对样品进行预测试,以便在使用定量方法(例如Spectroquant®测试)之前对铁浓度和可能的稀释因子进行估算。
我们所有的比色池和试剂测试试剂盒都配备了独特的实时ID(2维码),可实现无缝方法识别,并包含相关必要信息,例如批号、有效期和自动校准更新。
该Spectroquant® Reagent试剂测试盒包含高度稳定的即用型试剂混合物,用于根据随附说明书所述流程进行分析。

Legal Information

MQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany
SPECTROQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany


Still not finding the right product?

Explore all of our products under 铁测试


pictograms

Skull and crossbonesCorrosion

Hazard Classifications

Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Aquatic Chronic 3 - Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1B - Skin Sens. 1

存储类别

6.1B - Non-combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials

wgk

WGK 3

signalword

Danger



分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库


实验方案

The iron test enables quantification of iron ions in various waters. Iron ions are reduced to iron(II) ions that react with a triazine derivative to form a red-violet complex that is measured photometrically.

商品

Spectroquant® Iron Test - a suitable alternative to ICP or AAS for determination of iron in drinking water, mineral water, groundwater, and spring water.

Spectroquant®铁检测法——适宜的ICP或AAS替代方法,用于饮用水、矿泉水、地下水和泉水中铁的测定。

相关内容

饮用水检测技术包括定量检测、色谱法、分光光度法、反射法、物理参数测定(如浊点、颜色、硬度、pH、气味)和病原体检测(分子或细胞培养法)。这些质量控制试验既要在工艺过滤(絮凝和澄清等)后的输入水源中进行,也要在过滤后的输出用水中进行(如水龙头取样)。

Clean drinking water is essential for food and beverage production. This article gives an overview of chemical and microbiological testing of the drinking water for quality and safety.

查看所有相关内容




全球贸易项目编号

货号GTIN
P8001-25G04061832491080
P8001-5G04061834400745
114761000204022536963228
114761000104022536156576