登录 查看组织和合同定价。
选择尺寸
关于此项目
经验公式(希尔记法):
C4H8O
化学文摘社编号:
分子量:
72.11
UNSPSC Code:
12352115
EC Index Number:
201-159-0
MDL number:
NACRES:
NA.21
Grade:
ACS reagent
Assay:
≥99% (GC)
Bp:
79.6 °C/1013 hPa
Vapor pressure:
105 hPa ( 20 °C)
产品名称
2-Butanone, Meets ACS Specifications GR ACS
SMILES string
O=C(CC)C
InChI
1S/C4H8O/c1-3-4(2)5/h3H2,1-2H3
InChI key
ZWEHNKRNPOVVGH-UHFFFAOYSA-N
grade
ACS reagent
vapor pressure
105 hPa ( 20 °C)
assay
≥99% (GC)
form
liquid
dilution
(for analytical testing)
impurities
≤0.0005% Titrable acid
≤0.20% Water (H2O)
evapn. residue
≤0.0025%
color
APHA: ≤15
pH
7 (20 °C)
bp
79.6 °C/1013 hPa
mp
-86 °C
transition temp
flash point -4 °C
solubility
292 g/L
density
0.805 g/cm3 at 20 °C
shipped in
ambient
storage temp.
room temp
Quality Level
Analysis Note
Assay (GC): 99.0% min
Color (APHA): 15 max
Evaporation residue: 0.0025% max
Form: Clear liquid
Infrared Spectrum: Conforms to standard
Titrable acid: 0.0005meq/g max
Water (H2O): 0.20% max
Color (APHA): 15 max
Evaporation residue: 0.0025% max
Form: Clear liquid
Infrared Spectrum: Conforms to standard
Titrable acid: 0.0005meq/g max
Water (H2O): 0.20% max
Application
Meets ACS Specifications GR ACS
General description
EMPARTA solvents are designed for routine chemical synthesis, drying, purification, and critical labware cleaning in quality control environments. Engineered for precision, they deliver consistently reproducible results essential for rigorous validation and documentation.
Exceptional Quality Standards: These solvents meet or exceed ACS specifications, providing assurance of high quality that is crucial for accurate testing and analysis in quality control.
Consistent Reproducibility: Designed for precision, the solvents ensure that results can be reliably reproduced, which is vital for maintaining compliance and integrity in quality control processes.
Versatile Applications: Suitable for a variety of QC tasks, including analytical testing, method validation, and testing USP/NF monographs, these solvents support a comprehensive approach to quality assurance in laboratory settings.
Exceptional Quality Standards: These solvents meet or exceed ACS specifications, providing assurance of high quality that is crucial for accurate testing and analysis in quality control.
Consistent Reproducibility: Designed for precision, the solvents ensure that results can be reliably reproduced, which is vital for maintaining compliance and integrity in quality control processes.
Versatile Applications: Suitable for a variety of QC tasks, including analytical testing, method validation, and testing USP/NF monographs, these solvents support a comprehensive approach to quality assurance in laboratory settings.
Packaging
M-Bottle for Solvents
As a global leader in lab reagents, we are constantly looking for new ways to optimize the safety of our products. The newly developed 4L solvent bottle design features advanced sealing technology that eliminates leaks to make the handling of solvents safer and more convenient than ever before.
See all the new features here!
As a global leader in lab reagents, we are constantly looking for new ways to optimize the safety of our products. The newly developed 4L solvent bottle design features advanced sealing technology that eliminates leaks to make the handling of solvents safer and more convenient than ever before.
See all the new features here!
signalword
Danger
hcodes
Hazard Classifications
Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 3
target_organs
Central nervous system
supp_hazards
存储类别
3 - Flammable liquids
wgk
WGK 1
flash_point_f
26.6 °F - closed cup
flash_point_c
-3 °C - closed cup
法规信息
新产品
此项目有
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持