Quality Level
material
EPR seal, polypropylene
feature
hydrophilic
manufacturer/tradename
Polygard
parameter
4.8 bar max. differential pressure (70 psid) at 25 °C, 4.8 bar max. inlet pressure (70 psi) at 25 °C
cartridge nominal length
10 in. (25 cm)
diam.
7.0 cm (2.75 in.)
impurities
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
gravimetric extractables
≤50 mg
pore size
1.0 μm nominal pore size, 1.0 μm pore size
input
sample type liquid
cartridge code
Code 7 (2-226; O-rings w/locking-tabs)
General description
Device Configuration: Cartridge
Preparation Note
Sanitization Protocol
30 min with hot water @ 80 °C
30 min with hot water @ 80 °C
Sterilization Method
10 autoclave cycles or SIP @ 126 °C for 30 min
10 autoclave cycles or SIP @ 126 °C for 30 min
Analysis Note
Gravimetric Extractables: after 24-h soak in water
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥5 L
Legal Information
POLYGARD is a registered trademark of Merck KGaA, Darmstadt, Germany
Still not finding the right product?
Explore all of our products under Polygard-CR 筒式过滤器 10 in.1.0 µm 7 号 乙丙橡胶
全球贸易项目编号
| 货号 | GTIN |
|---|---|
| CR0171E06 | 04053252563690 |