产品名称

Polysep II 2.0/1.2 µm 标称, Opticap® XL 囊式, pore size 2.0/1.2 μm, Chemistry: Mixed Cellulose Esters (MCE)Inlet: 3/4 in. Sanitary FlangeOutlet: 9/16 in. Hose BarbMax Operating Pressure: 80 psi @ 25 °C, Opticap® XL 2, cartridge nominal length 2 in. (5 cm), filter diam. 5.7 in. (14.5 cm)

material

borosilicate glass fiber (BGF) membrane, mixed cellulose esters (MCE) membrane, polypropylene filter, polypropylene housing, polypropylene support, silicone seal

reg. compliance

FDA 21CFR177-182 (all component materials)

Quality Level

sterility

non-sterile

sterilization compatibility

autoclavable compatible

product line

Opticap® XL 2

feature

hydrophilic

manufacturer/tradename

Opticap®

parameter

1 bar max. inlet pressure (15 psi) at 80 °C, 2.75 bar max. inlet pressure (40 psi) at 60 °C, 25 °C max. inlet temp., 3.5 bar max. differential pressure (50 psid) at 25 °C, 5.5 bar max. inlet pressure (80 psi) at 23 °C, 80 psig max. inlet pressure

technique(s)

prefiltration: suitable

cartridge nominal length

2 in. (5 cm)

device L

14.2 cm (5.6 in.)

device size

2 in.

filter diam.

5.7 in. (14.5 cm)

filter filtration area

0.06 m2

inlet connection diam.

3/4 in.

inlet to outlet width

14.2 cm (5.6 in.)

outlet connection diam.

9/16 in.

impurities

≤0.5 EU/mL bacterial endotoxins (LAL test, aqueous extraction), <0.5 EU/mL bacterial endotoxins (LAL test, sample aqueous extraction)

matrix

Polysep II

pore size

2.0/1.2 μm nominal pore size, 2.0/1.2 μm pore size

fitting

(19 mm (3/4 in.) Sanitary Flange Inlet and 14 mm (9/16 in.) Hose Barb Outlet)

正在寻找类似产品? 访问 产品对比指南

General description

Device Configuration: Capsule

Features and Benefits

Double Layer

Packaging

Double Easy-Open bag

Preparation Note

Sterilization Method:
3 autoclave cycles of Sterilization Method: 30min at 121°C; not in-line steam sterilizable

This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21CFR210.3(b)(6).

Analysis Note

Gravimetric Extractables: ≤ 45 mg per capsule after a 600 mL flush and 24 hours in water at controlled room temperature.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥ 1 L

Other Notes

Directions for Use:

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer first page of Visual Inspection Guide and introduction section of Mixed cellulose esters Tech Brief
  • Storage Statement: Please refer Mixed cellulose esters Tech Brief
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

Legal Information

OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany
Polysep is a trademark of Sigma-Aldrich Co. LLC

法规信息

新产品
此项目有

分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持