material
PTFE membrane, high-density polyethylene housing
sterility
non-sterile
product line
Millex™
feature
holdup volume< 10 μL, hydrophilic
manufacturer/tradename
Millex™
parameter
14 bar max. inlet pressure (200 psi), 45 °C max. temp.
technique(s)
LC/MS: suitable, UHPLC-MS: suitable, UHPLC: suitable, analytical sample preparation: suitable, mass spectrometry (MS): suitable
H
19.8 mm
diam.
4 mm
filtration area
0.1 cm2
volume
1 mL
pore size
0.2 μm
input
sample type aqueous solution(s)
sample type organic solution(s)
fitting
female Luer-Lok® inlet, male Luer outlet stepped slip
shipped in
ambient
正在寻找类似产品? 访问 产品对比指南
General description
•最低萃取物,优化了UHPLC和LC-MS等敏感分析的背景水平
•过滤含蛋白质的溶液以及水溶液或有机溶液
•提供 0.20 µm和0.45 µm 的孔径和三种直径,以满足您的应用需求
提供多种包装尺寸:
以NS(-------NS)结尾的SKU:50个/包
以 NL(------- NL)结尾的SKU:100个/包
以 NB(-------NB)结尾的SKU:250个/包
以NK(-------NK)结尾的SKU:1000个/包
SLCRT13NL:100个/包这些针头式过滤器有一个管出口
应用:
UHPLC、HPLC和质谱分析之前的样品过滤;溶剂过滤;水溶液和有机溶液的澄清
Application
Features and Benefits
Packaging
Physical form
Legal Information
商品
The possible causes and potential remedies for challenges encountered as a result of blocking, washing, antibody incubation, and detection/exposure of Western blots
Prior to probing a membrane using precious antibodies, it is helpful to visualize the transferred proteins on the blot to ensure complete transfer and even loading. This page describes possible causes and potential remedies for challenges encountered during protein visualization.
Millex® hydrophilic PTFE syringe filters offer broad chemical compatibility and robust performance for various sample filtrations.
Improve your mass spectra with strategies to optimize sample preparation in protein and small molecule mass spectrometry.
相关内容
Because of its high sensitivity and extreme versatility, mass spectrometry has become a popular technique for identifying and quantifying molecules within complex mixtures, in diverse research areas that range from systems biology and proteomics to environmental analysis. Successful mass spectrometry requires extremely areful sample preparation, in order to avoid complexity of the mixtures being analyzed. EMD Millipore supports researchers using mass spectrometry with tools or multiple steps of the workflow, including purification, clarification, and analysis.
"Liquid chromatography mass spectrometry (LC-MS) and gas chromatography mass spectrometry (GC-MS) are being increasingly used in analysis of samples, not only in the biotechnology and pharmaceutical industries, but also more generally in the analysis, identification and quantitation of complex samples containing low levels of analytes. The advantages of LC-MS or GC-MS over other analytical techniques include high sensitivityand specificity for analyte detection and quantitation."
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.