跳转至内容
Merck
CN

11449460001

Roche

DNA Molecular Weight Marker IX

solution, pkg of 50 μg (in 200 μl)

别名:

DNA marker

登录 查看组织和合同定价。

选择尺寸


关于此项目

UNSPSC Code:
41105335
NACRES:
NA.54
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

产品名称

DNA Molecular Weight Marker IX, solution, pkg of 50 μg (in 200 μl)

color

colorless

form

solution

packaging

pkg of 50 μg (in 200 μl)

manufacturer/tradename

Roche

concentration

250 μg/mL

solubility

water: miscible

storage temp.

−20°C

Quality Level

Application

DNA Molecular Weight Marker IX is especially designed for the analysis of mid-size PCR products in agarose gels. It simplifies accurate molecular weight determination of double-stranded DNA fragments generated by:
  • Restriction digests
  • PCR
  • RT-PCR

General description

DNA Molecular Weight Marker IX contains a mixture of eleven DNA fragments. The mixture is obtained by cleavage of φX 174 DNA with restriction endonuclease Hae III.
Size Range: 72 to 1353 bp

Other Notes

50 μg = 1A260 unit
For life science research only. Not for use in diagnostic procedures.
The mixture contains eleven DNA fragments with the following base pair lengths (1 base pair = 660 Daltons): 72, 118, 194, 234, 271, 281, 310, 603, 872, 1078, and 1353.
Note: Fragment lengths are derived from computer analysis of the DNA sequence. Depending on the size range of the marker, the smallest fragments will only be visible on overloaded gels.

Preparation Note

Storage conditions (working solution): 2 to 8 °C
Once thawed we recommend further storage at 2 to 8 °C.

存储类别

12 - Non Combustible Liquids

wgk

nwg

flash_point_f

does not flash

flash_point_c

does not flash

法规信息

新产品
此项目有

历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Patrizia Spigaglia et al.
Journal of medical microbiology, 53(Pt 11), 1129-1136 (2004-10-22)
Recent studies have shown that Clostridium difficile strains with variant toxins and those with resistance to macrolide-lincosamide-streptogramin B (MLSB) are increasingly causing severe disease and outbreaks in hospital settings. Here, the pathogenicity locus (PaLoc), the acquisition of binary toxin, and
C N Okeke et al.
Journal of clinical microbiology, 39(10), 3491-3494 (2001-09-28)
The LightCycler system (two-step reverse transcription-PCR-fluorescent hybridization [LC RT-PCR-FH]) was used to quantify Candida albicans actin mRNA as a means of assessing its viability in a reconstituted skin model of cutaneous candidiasis following the application of an antimycotic. A 192-bp

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持