产品名称
DNA Molecular Weight Marker IX, solution, pkg of 50 μg (in 200 μl)
color
colorless
form
solution
packaging
pkg of 50 μg (in 200 μl)
manufacturer/tradename
Roche
concentration
250 μg/mL
solubility
water: miscible
storage temp.
−20°C
Quality Level
Application
DNA Molecular Weight Marker IX is especially designed for the analysis of mid-size PCR products in agarose gels. It simplifies accurate molecular weight determination of double-stranded DNA fragments generated by:
- Restriction digests
- PCR
- RT-PCR
General description
DNA Molecular Weight Marker IX contains a mixture of eleven DNA fragments. The mixture is obtained by cleavage of φX 174 DNA with restriction endonuclease Hae III.
Size Range: 72 to 1353 bp
Size Range: 72 to 1353 bp
Other Notes
50 μg = 1A260 unit
For life science research only. Not for use in diagnostic procedures.
The mixture contains eleven DNA fragments with the following base pair lengths (1 base pair = 660 Daltons): 72, 118, 194, 234, 271, 281, 310, 603, 872, 1078, and 1353.
Note: Fragment lengths are derived from computer analysis of the DNA sequence. Depending on the size range of the marker, the smallest fragments will only be visible on overloaded gels.
Note: Fragment lengths are derived from computer analysis of the DNA sequence. Depending on the size range of the marker, the smallest fragments will only be visible on overloaded gels.
Preparation Note
Storage conditions (working solution): 2 to 8 °C
Once thawed we recommend further storage at 2 to 8 °C.
Once thawed we recommend further storage at 2 to 8 °C.
存储类别
12 - Non Combustible Liquids
wgk
nwg
flash_point_f
does not flash
flash_point_c
does not flash
法规信息
新产品
此项目有
Patrizia Spigaglia et al.
Journal of medical microbiology, 53(Pt 11), 1129-1136 (2004-10-22)
Recent studies have shown that Clostridium difficile strains with variant toxins and those with resistance to macrolide-lincosamide-streptogramin B (MLSB) are increasingly causing severe disease and outbreaks in hospital settings. Here, the pathogenicity locus (PaLoc), the acquisition of binary toxin, and
C N Okeke et al.
Journal of clinical microbiology, 39(10), 3491-3494 (2001-09-28)
The LightCycler system (two-step reverse transcription-PCR-fluorescent hybridization [LC RT-PCR-FH]) was used to quantify Candida albicans actin mRNA as a means of assessing its viability in a reconstituted skin model of cutaneous candidiasis following the application of an antimycotic. A 192-bp
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持