等级
SAJ first grade
蒸汽密度
4.46 (vs air)
蒸汽压
1.9 mmHg ( 20 °C)
方案
≥98.0%
表单
liquid
自燃温度
594 °F
expl. lim.
10 %
存货情况
available only in Japan
折射率
n20/D 1.417 (lit.)
pH值(酸碱度)
11.1 (20 °C, 1 g/L)
沸点
159 °C (lit.)
mp
−62 °C (lit.)
密度
0.767 g/mL at 25 °C (lit.)
SMILES字符串
CCCCNCCCC
InChI
1S/C8H19N/c1-3-5-7-9-8-6-4-2/h9H,3-8H2,1-2H3
InChI key
JQVDAXLFBXTEQA-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
警示用语:
Danger
危险分类
Acute Tox. 2 Inhalation - Acute Tox. 3 Dermal - Acute Tox. 4 Oral - Eye Dam. 1 - Flam. Liq. 3 - Skin Corr. 1A
储存分类代码
3 - Flammable liquids
WGK
WGK 1
闪点(°F)
104.9 °F - closed cup
闪点(°C)
40.5 °C - closed cup
个人防护装备
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
法规信息
新产品
此项目有
Baiyi Xue et al.
Journal of mass spectrometry : JMS, 46(7), 689-695 (2011-07-12)
Characterization of glycosaminoglycans poses a challenge for current analytical techniques, as they are highly acidic, polydisperse and heterogeneous compounds. The purpose of this study is the separation and analysis of a partially depolymerized heparin-like glycosaminoglycan by on-line ion-pairing reversed-phase high-performance
Asa Marand et al.
Journal of environmental monitoring : JEM, 7(4), 335-343 (2005-03-31)
The solvent-free sampler for airborne isocyanates consisted of a polypropylene tube with an inner wall coated with a glass fibre filter, coupled in series with a 13 mm glass fibre filter. The filters were impregnated with reagent solution containing equimolar
Ivana Bobeldijk et al.
The Annals of occupational hygiene, 52(8), 757-763 (2008-09-25)
An adapted method for the quantitative determination of isocyanates in air was implemented and validated in-house. The method was based on air sampling using an impinger flask containing di-n-butylamine (DBA) in toluene and a glass fibre filter in series. The
L Airoldi et al.
Toxicology, 43(2), 217-225 (1987-02-01)
The effect of the food additive butylated hydroxyanisole on the nitrosation of dibutylamine was studied in vitro and in vivo, in rats. At the highest concentration tested, butylated hydroxyanisole significantly inhibited the in vitro formation of N-nitrosodi-n-butylamine from dibutylamine and
R Batlle et al.
Fresenius' journal of analytical chemistry, 371(4), 514-518 (2002-01-05)
The design and evaluation of a portable diffusive sampler for isocyanates is described. The sampler employs dibutylamine (DBA) loaded onto 60-microm polydimethylsiloxane-divinylbenzene (PDMS-DVB) solid-phase microextraction (SPME) fibers. The DBA-isocyanate derivative is then desorbed by sonication and analyzed by LC-MS using