登录 查看组织和合同定价。
选择尺寸
关于此项目
线性分子式:
BrCH2CH2NH2 · HBr
化学文摘社编号:
分子量:
204.89
UNSPSC Code:
12352100
NACRES:
NA.22
PubChem Substance ID:
EC Number:
219-924-2
Beilstein/REAXYS Number:
3607605
MDL number:
Assay:
≥97.0% (AT)
Form:
crystalline
InChI key
WJAXXWSZNSFVNG-UHFFFAOYSA-N
InChI
1S/C2H6BrN.BrH/c3-1-2-4;/h1-2,4H2;1H
SMILES string
Br.NCCBr
grade
purum
assay
≥97.0% (AT)
form
crystalline
bp
181.3 °C/979.2 hPa
mp
170-175 °C (lit.), 170-175 °C
solubility
water: soluble 84.02 g/L at 28 °C, soluble
density
0.98 g/cm3 at 28.3 °C
functional group
amine, bromo
Quality Level
正在寻找类似产品? 访问 产品对比指南
Application
2-溴乙胺氢溴酸盐(BEA-HBr)可用作反应物制备:
也可用作尼龙表面改性的烷基化剂,以获得伯/仲/叔胺基。
- 氨基功能化离子液体,1-胺乙基-3-甲基咪唑六氟磷酸盐([2-aemim][PF6])。[2-aemim][PF6]可作为芳族醛、丙二腈、乙酰乙酸乙酯发生Knoevenagel缩合反应合成4H-吡喃衍生物的催化剂。
- 通过环缩合反应合成2-(N-aryl-N-芳酰基)氨基-4,5-二氢噻唑衍生物的催化剂。
也可用作尼龙表面改性的烷基化剂,以获得伯/仲/叔胺基。
signalword
Warning
hcodes
Hazard Classifications
Acute Tox. 4 Oral - Aquatic Chronic 3
存储类别
13 - Non Combustible Solids
wgk
WGK 3
flash_point_f
142.9 °F - Pensky-Martens closed cup
flash_point_c
61.6 °C - Pensky-Martens closed cup
ppe
dust mask type N95 (US), Eyeshields, Gloves
Amino-functionalized ionic liquid as an efficient and recyclable catalyst for Knoevenagel reactions in water
Cai Y, et al.
Catalysis Letters, 109(1-2), 61-64 (2006)
Synthesis and QSAR Studies in 2-(N-aryl-N-aroyl) amino-4, 5-dihydrothiazole Derivatives as Potential Antithrombotic Agents
Saxena AK, et al.
Bioorganic & Medicinal Chemistry, 9(8), 2025-2034 (2001)
Nylon surface modification. Part 1. Targeting the amide groups for selective introduction of reactive functionalities
Jia X, et al.
Polymer, 47(14), 4916-4924 (2006)
G Bergström et al.
Journal of hypertension, 19(3 Pt 2), 659-665 (2001-05-01)
Restoring renal perfusion pressure (unclipping) of one-kidney-one-clip renal hypertensive (1 K1C) rats normalizes mean arterial pressure (MAP) rapidly. This has been attributed to salt/volume losses or release of the putative renal medullary depressor hormone (RMDH). To investigate the effects of
Samer Sourial et al.
Biomarkers : biochemical indicators of exposure, response, and susceptibility to chemicals, 15(5), 424-435 (2010-05-25)
Currently there are no biomarkers for detecting collecting duct damage in man. Antibodies to several collecting duct-specific antigens exist but sandwich assays have been difficult to establish due to the need for two different antibodies to the same protein. We
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持