Merck
CN

09709

Sigma-Aldrich

磷酸二氢铵

BioUltra, ≥99.5% (T)

登录查看公司和协议定价

别名:
prim -磷酸铵, -磷酸铵, 磷酸二氢铵
线性分子式:
NH4H2PO4
CAS号:
分子量:
115.03
EC 号:
MDL编号:
PubChem化学物质编号:
NACRES:
NA.25

产品线

BioUltra

质量水平

检测方案

≥99.5% (T)

杂质

insoluble matter, passes filter test

pH值(酸碱度)

4.0-5.0 (25 °C, 0.1 M in H2O)

mp

190 °C (dec.) (lit.)

溶解性

H2O: 0.1 M at 20 °C, clear, colorless

痕量阴离子

chloride (Cl-): ≤50 mg/kg
sulfate (SO42-): ≤50 mg/kg

痕量阳离子

Al: ≤5 mg/kg
As: ≤0.5 mg/kg
Ba: ≤5 mg/kg
Bi: ≤5 mg/kg
Ca: ≤50 mg/kg
Cd: ≤5 mg/kg
Co: ≤5 mg/kg
Cr: ≤5 mg/kg
Cu: ≤5 mg/kg
Fe: ≤20 mg/kg
K: ≤50 mg/kg
Li: ≤5 mg/kg
Mg: ≤5 mg/kg
Mn: ≤5 mg/kg
Mo: ≤5 mg/kg
Na: ≤50 mg/kg
Ni: ≤5 mg/kg
Pb: ≤5 mg/kg
Sr: ≤5 mg/kg
Zn: ≤5 mg/kg

λ

0.1 M in H2O

紫外吸收

λ: 260 nm Amax: ≤0.059
λ: 280 nm Amax: ≤0.050

SMILES string

N.OP(O)(O)=O

InChI

1S/H3N.H3O4P/c;1-5(2,3)4/h1H3;(H3,1,2,3,4)

InChI key

LFVGISIMTYGQHF-UHFFFAOYSA-N

正在寻找类似产品? Visit 产品对比指南

应用

磷酸二氢铵可用于研究优化试剂、蛋白质结构分析、蛋白质组学、X 射线晶体学和生物缓冲液。磷酸二氢铵已被用于开发一种简单的高效液相色谱方法,用于测定尿液中的 N1-烷基烟酰胺,包括 C1C5 烷基衍生物。磷酸二氢铵还被用于开发一种将高效液相色谱分析与紫外检测(254 nm)相结合的方法,用于测定人血浆中咪达唑仑及其两种羟基化代谢物。

其他说明

培养基的组分,例如 DEV SIMMONS柠檬酸琼脂、醋酸盐琼脂(根据 Trabulsi 和 Ewing 的方法)

储存分类代码

11 - Combustible Solids

WGK

WGK 1

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

Eyeshields, Gloves, type N95 (US)


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

为方便起见,与您过往购买产品相关的文件已保存在文档库中。

访问文档库

难以找到您所需的产品或批次号码?

在网站页面上,产品编号会附带包装尺寸/数量一起显示(例如:T1503-25G)。请确保 在“产品编号”字段中仅输入产品编号 (示例: T1503).

示例

T1503
货号
-
25G
包装规格/数量

其它示例:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

输入内容 1.000309185)

遇到问题?欢迎随时联系我们技术服务 寻求帮助

批号可以在产品标签上"批“ (Lot或Batch)字后面找到。

Aldrich 产品

  • 如果您查询到的批号为 TO09019TO 等,请输入去除前两位字母的批号:09019TO。

  • 如果您查询到的批号含有填充代码(例如05427ES-021),请输入去除填充代码-021的批号:05427ES。

  • 如果您查询到的批号含有填充代码(例如 STBB0728K9),请输入去除填充代码K9的批号:STBB0728。

未找到您寻找的产品?

部分情况下,可能未在线提供COA。如果搜索不到COA,可在线索取。

索取COA

T Hirayama et al.
Analytical biochemistry, 147(1), 108-113 (1985-05-15)
A simple high-performance liquid chromatographic method has been developed for determining N1-alkylnicotinamides, including C1-C5 alkyl derivatives, in urine. N1-Alkylnicotinamides were reacted with acetophenone in strong alkali medium at 0 degrees C and then formic acid was added. The reaction mixture
L.R. Trabulsi et al.
Publ. Hlth. Lab., 20, 137-137 (1962)
María J Nozal et al.
Journal of pharmaceutical and biomedical analysis, 30(2), 285-291 (2002-08-23)
A high performance liquid chromatographic (HPLC) method for the assay of sumatriptan succinate residues in swabs collected from manufacturing equipment surfaces was developed and validated in order to control a cleaning procedure. The swabbing procedure using two cotton swabs moistened
D Crutchik et al.
Water science and technology : a journal of the International Association on Water Pollution Research, 64(12), 2460-2467 (2011-12-16)
Struvite crystallization (MgNH(4)PO(4)·6H(2)O, MAP) could be an alternative for the sustainable and economical recovery of phosphorus from concentrated wastewater streams. Struvite precipitation is recommended for those wastewaters which have high orthophosphate concentration. However the presence of a cheap magnesium source
Pin Gao et al.
Bioresource technology, 102(3), 3645-3648 (2010-12-15)
Effects of different pretreatment protocols in (NH(4))(2)HPO(4) activation of rice straw on porous activated carbon evolution were evaluated. The pore structure, morphology and surface chemistry of obtained activated carbons were investigated by nitrogen adsorption, scanning electron microscopy and Fourier transform

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门