Merck
CN

21193

Supelco

钙离子载体 II

Selectophore, function tested

登录查看公司和协议定价

别名:
N , N , N ′,N四 [环己基] 二乙醇酸二酰胺, N , N , N ′,N四环已基-3-氧杂戊二酰胺, ETH 129
经验公式(希尔记法):
C28H48N2O3
CAS号:
分子量:
460.69
Beilstein:
6491651
MDL编号:
PubChem化学物质编号:
NACRES:
NB.61

等级

for ion-selective electrodes

质量水平

产品线

Selectophore

形式

solid

质量

function tested

SMILES字符串

O=C(COCC(=O)N(C1CCCCC1)C2CCCCC2)N(C3CCCCC3)C4CCCCC4

InChI

1S/C28H48N2O3/c31-27(29(23-13-5-1-6-14-23)24-15-7-2-8-16-24)21-33-22-28(32)30(25-17-9-3-10-18-25)26-19-11-4-12-20-26/h23-26H,1-22H2

InChI key

URAUKAJXWWFQSU-UHFFFAOYSA-N

正在寻找类似产品? Visit 产品对比指南

一般描述

请访问我们的 传感器应用页面 以了解更多信息。

应用

精选应用实例
适用于细胞内钙测定
采用钙离子载体 (ETH 129) 制备了用于测定解离常数 (K d ) 的钙离子选择性微电极。
用于制作钙离子选择电极的亲脂性离子载体,该离子电极的检测限可以达到亚钠摩尔级。高效钙离子载体;在膜中对 Ca2+ 的选择性大约为 Mg2+ 的 104 倍。

包装

无底玻璃瓶。内含物在插入的融合锥体内。

法律信息

Selectophore is a trademark of Merck KGaA, Darmstadt, Germany

储存分类代码

11 - Combustible Solids

WGK

WGK 3

闪点(°F)

Not applicable

闪点(°C)

Not applicable

个人防护装备

dust mask type N95 (US), Eyeshields, Gloves


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

为方便起见,与您过往购买产品相关的文件已保存在文档库中。

访问文档库

难以找到您所需的产品或批次号码?

在网站页面上,产品编号会附带包装尺寸/数量一起显示(例如:T1503-25G)。请确保 在“产品编号”字段中仅输入产品编号 (示例: T1503).

示例

T1503
货号
-
25G
包装规格/数量

其它示例:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

输入内容 1.000309185)

遇到问题?欢迎随时联系我们技术服务 寻求帮助

批号可以在产品标签上"批“ (Lot或Batch)字后面找到。

Aldrich 产品

  • 如果您查询到的批号为 TO09019TO 等,请输入去除前两位字母的批号:09019TO。

  • 如果您查询到的批号含有填充代码(例如05427ES-021),请输入去除填充代码-021的批号:05427ES。

  • 如果您查询到的批号含有填充代码(例如 STBB0728K9),请输入去除填充代码K9的批号:STBB0728。

未找到您寻找的产品?

部分情况下,可能未在线提供COA。如果搜索不到COA,可在线索取。

索取COA

G Prestipino et al.
Analytical biochemistry, 210(1), 119-122 (1993-04-01)
We have investigated the ability of the neutral ionophore ETH 129 to translocate Ca2+ across artificial and biological membranes. ETH 129 induces Ca2+ transport across planar lipid bilayer. The zero-current membrane potential in a gradient of Ca2+ concentration exhibits Nernst
Mariya V Kovaleva et al.
Journal of bioenergetics and biomembranes, 41(3), 239-249 (2009-07-18)
In this study we used tightly-coupled mitochondria from Yarrowia lipolytica and Dipodascus (Endomyces) magnusii yeasts, possessing a respiratory chain with the usual three points of energy conservation. High-amplitude swelling and collapse of the membrane potential were used as parameters for
Iwona Bedlechowicz-Sliwakowska et al.
Analytical and bioanalytical chemistry, 385(8), 1477-1482 (2006-07-19)
In this work, ion-selective electrodes for calcium ion were investigated. Two ionophores were used in the membranes: ETH 1001 and ETH 129. An internal filling solution buffered for primary ion was used that allowed the lower detection limit to be
N Abramova et al.
Talanta, 113, 31-35 (2013-05-28)
An analytical system based on ion-selective field effect transistors (ISFETs) with Ca(2+) ion selective photocurable membranes is developed to offer a semiautomatic analysis of serum calcium concentration of ruminants. Optimisation of ion-sensitive membrane composition containing different copolymerised plasticizers was performed
Patrick C Bradshaw et al.
BMC biochemistry, 7, 4-4 (2006-02-08)
Divalent cations are required for many essential functions of mitochondrial metabolism. Yet the transporters that mediate the flux of these molecules into and out of the mitochondrion remain largely unknown. Previous studies in yeast have led to the molecular identification

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门