跳转至内容
Merck
CN

33490

HMDI

analytical standard

别名:

4,4′-二异氰酸酯二环己基甲烷, 1,1′-亚甲二(4-异氰酸基环己烷), 4,4′-HMDI, 二环己基甲烷-4,4′-二异氰酸酯

登录 查看公司和协议定价

选择尺寸


关于此项目

线性分子式:
CH2(C6H10NCO)2
化学文摘社编号:
分子量:
262.35
Beilstein:
2217800
EC 号:
MDL编号:
UNSPSC代码:
41116107
PubChem化学物质编号:
NACRES:
NA.24
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

等级

analytical standard

质量水平

质量

mixture of isomers

保质期

limited shelf life, expiry date on the label

技术

HPLC: suitable
gas chromatography (GC): suitable

应用

environmental

包装形式

neat

SMILES字符串

O=C=NC1CCC(CC1)CC2CCC(CC2)N=C=O

InChI

1S/C15H22N2O2/c18-10-16-14-5-1-12(2-6-14)9-13-3-7-15(8-4-13)17-11-19/h12-15H,1-9H2

InChI key

KORSJDCBLAPZEQ-UHFFFAOYSA-N

正在寻找类似产品? 访问 产品对比指南

一般描述

该物质被列入欧盟法规10/2011中关于拟与食品接触的塑料的积极清单。

应用

有关合适仪器技术的更多信息,请参考产品分析证书。如需进一步支持,请联系技术服务部门。

象形图

Skull and crossbonesHealth hazard

警示用语:

Danger

危险分类

Acute Tox. 2 Inhalation - Eye Irrit. 2 - Resp. Sens. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3

靶器官

Respiratory system

储存分类代码

6.1A - Combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials

WGK

WGK 1

闪点(°F)

235.4 °F - closed cup

闪点(°C)

113 °C - closed cup

个人防护装备

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Y M Sun et al.
Biomaterials, 18(7), 527-533 (1997-04-01)
Composite membranes were prepared by casting a linear poly(2-hydroxyethyl methacrylate) (pHEMA) solution onto polyester non-woven supports, and then the supported pHEMA within the membranes was cross-linked by a diisocyanate cross-linking agent to form a network structure. The swelling and permeation
Tzu-Wen Chuang et al.
Journal of biomedical materials research. Part A, 86(3), 648-661 (2007-11-21)
Poor compatibility between blood and metallic coronary artery stents is one reason for arterial restenosis; however, the immobilization of anticoagulant agents on the surface of the stent is a feasible method of improving stent compatibility. Heparin, a well-known anticoagulant, has
I R White et al.
Contact dermatitis, 9(4), 300-303 (1983-07-01)
Organic di-isocyanates are used widely in industry. The concomitant respiratory complications are well-known. Cutaneous problems precipitated by skin contact with these chemicals are less well recognised. Allergic contact dermatitis caused by exposure to di-cyclohexylmethane 4,4'-di-isocyanate has been demonstrated in a
T-W Chuang et al.
Journal of biomedical materials research. Part A, 85(3), 722-730 (2007-09-28)
Poor compatibility between blood and metallic coronary artery stents is one reason for arterial restenosis. Immobilization of anticoagulant agents on the stent's surface is feasible for improving compatibility. We examined possible surface-coupling agents for anticoagulant agent immobilization. Hexamethylene diisocyanate (HMDI)
L H Chan-Chan et al.
Acta biomaterialia, 6(6), 2035-2044 (2009-12-17)
Biodegradable segmented polyurethanes (BSPUs) were prepared with poly(caprolactone) as a soft segment, 4,4'-methylene bis (cyclohexyl isocyanate) and either butanediol (BSPU1) or dithioerythritol (BSPU2) as a chain extender. BSPU samples were characterized in terms of their physicochemical properties and their hemocompatibility.

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持