蒸汽密度
3 (20 °C, vs air)
质量水平
蒸汽压
73 mmHg ( 20 °C)
方案
≥99.8% (GC)
自燃温度
801 °F
expl. lim.
2.2-11.5 %, 38 °F
技术
HPLC: suitable
gas chromatography (GC): suitable
杂质
≤0.02% water
蒸发残留物
≤0.0005%
折射率
n20/D 1.3720 (lit.)
n20/D 1.372
沸点
76.5-77.5 °C (lit.)
mp
−84 °C (lit.)
密度
0.902 g/mL at 25 °C (lit.)
适用性
suitable for residue analysis
SMILES字符串
CCOC(C)=O
InChI
1S/C4H8O2/c1-3-6-4(2)5/h3H2,1-2H3
InChI key
XEKOWRVHYACXOJ-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
一般描述
用 GC/ECD 分析时,在林丹到 DDT 的保留时间范围内没有响应信号超过 5ng/l 林丹的杂质存在。
应用
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
警示用语:
Danger
危险声明
危险分类
Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 3
靶器官
Central nervous system
补充剂危害
储存分类代码
3 - Flammable liquids
WGK
WGK 1
闪点(°F)
26.6 °F - closed cup
闪点(°C)
-3.0 °C - closed cup
个人防护装备
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
法规信息
新产品
此项目有
Flavio G Rocha et al.
Biomaterials, 29(19), 2884-2890 (2008-04-09)
Our group has previously created a functional neointestine that is capable of restoring absorptive function. However, the endogenous level of vascular endothelial growth factor (VEGF) is markedly reduced in the construct compared to native bowel. Therefore, we wanted to locally
Jun He et al.
Journal of chromatography. A, 1216(5), 845-856 (2008-12-27)
A mixture of two molecular micelles polysodium N-undecenoxy carbonyl-L-leucinate, (poly-L-SUCL) and polysodium N-undecanoyl leucylvalinate, (poly-L-SULV) was utilized in micellar electrokinetic chromatography-electrospray ionization-mass spectrometry (MEKC-ESI-MS) to simultaneously separate and detect enantiomers of binaphthyl derivatives. Separation parameters such as background buffer composition
Lisa Amanda Holm Rottbøll et al.
Basic & clinical pharmacology & toxicology, 117(4), 242-250 (2015-04-02)
Recent intrabronchial microdialysis data indicate that the respiratory epithelium is highly permeable to drugs. Of concern is whether intrabronchial microdialysis disrupts the integrity of the respiratory epithelium and thereby alters drug penetration into the pulmonary epithelial lining fluid (PELF). The
K J S Anand et al.
British journal of anaesthesia, 101(5), 680-689 (2008-08-30)
Relationships between plasma morphine concentrations and neonatal responses to endotracheal tube (ETT) suctioning are unknown in preterm neonates. Ventilated preterm neonates (n=898) from 16 centres were randomly assigned to placebo (n=449) or morphine (n=449). After an i.v. loading dose (100
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持
