InChI key
LLHKCFNBLRBOGN-UHFFFAOYSA-N
InChI
1S/C6H12O3/c1-5(4-8-3)9-6(2)7/h5H,4H2,1-3H3
SMILES string
COCC(C)OC(C)=O
vapor pressure
3.7 mmHg ( 20 °C)
assay
99%
autoignition temp.
669 °F
expl. lim.
13.1 %
Gene Information
human ... AR(367), IMPDH2(3615), NR3C1(2908), PGR(5241)
density
0.970 g/mL at 25 °C (lit.)
正在寻找类似产品? 访问 产品对比指南
Other Notes
This product has been replaced by 484431-Sigma-Aldrich | Propylene glycol monomethyl ether acetate, ≥99.5% | CH3CO2CH(CH3)CH2OCH3
signalword
Warning
hcodes
Hazard Classifications
Flam. Liq. 3
存储类别
3 - Flammable liquids
wgk
WGK 1
flash_point_f
113.9 °F - closed cup
flash_point_c
45.5 °C - closed cup
法规信息
新产品
此项目有
Limor Cohen et al.
ACS nano, 14(8), 9491-9501 (2020-06-27)
Many proteins are present at low concentrations in biological samples, and therefore, techniques for ultrasensitive protein detection are necessary. To overcome challenges with sensitivity, the digital enzyme-linked immunosorbent assay (ELISA) was developed, which is 1000× more sensitive than conventional ELISA
Simon Braun et al.
Proceedings of the National Academy of Sciences of the United States of America, 112(12), 3641-3646 (2015-03-17)
The dynamics of quantum phase transitions pose one of the most challenging problems in modern many-body physics. Here, we study a prototypical example in a clean and well-controlled ultracold atom setup by observing the emergence of coherence when crossing the
Sara Sheikhzadeh et al.
Orphanet journal of rare diseases, 9, 203-203 (2014-12-11)
Echocardiographic upper normal limits of both main pulmonary artery (MPA) diameters (MPA-d) and ratio of MPA to aortic root diameter (MPA-r) are not defined in healthy adults. Accordingly, frequency of MPA dilatation based on echocardiography remains to be assessed in
Shaohua Ma et al.
Lab on a chip, 14(18), 3611-3620 (2014-07-30)
The flow topology in moving microdroplets has a significant impact on the behaviour of encapsulated objects and hence on applications of the technology. This study reports on a systematic investigation of the flow field inside droplets moving in a rectangular
Takuya Miyano et al.
International journal of pharmaceutics, 475(1-2), 504-513 (2014-09-15)
In process analytical technology (PAT) based on near infrared (NIR) spectroscopy, wavenumber selection is crucial to develop an accurate and robust calibration model. The present research proposes new efficient spectral dividing and wavenumber selection methods to significantly reduce the computational
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持