InChI key
OPCMAZHMYZRPID-UHFFFAOYSA-J
SMILES string
[K+].[K+].I[Hg--](I)(I)I
InChI
1S/Hg.4HI.2K/h;4*1H;;/q+2;;;;;2*+1/p-4
form
liquid
quality
for qualitative det. of ammonia and ammonium compounds
specific analyte(s)
ammonium
technique(s)
photometry: suitable
impurities
potassium hydroxide, potassium tetraiodomercurate
density
1.16 g/mL at 20 °C
application(s)
environmental
food and beverages
general analytical
Quality Level
正在寻找类似产品? 访问 产品对比指南
General description
奈斯勒试剂广泛用于测定铵化合物。可以使用无水碘化汞和无水碘化钾制备。可以由溶解在氢氧化钾中的四碘酸钾制备。
Application
奈斯勒试剂已用于流动分析方案中分析光谱法测氨。
Other Notes
方法检出限为0.1 mg/L。
参考文献: APHA 1975。
参考文献: APHA 1975。
用于氨测定的试剂
Disclaimer
存放时可能形成少量沉淀
对于美国客户:本品含汞。废弃后切勿放入垃圾桶,须按照地方、州或联邦法律处置。


signalword
Danger
Hazard Classifications
Acute Tox. 2 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Aquatic Acute 1 - Aquatic Chronic 1 - Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1A - STOT RE 2
target_organs
Kidney,Central nervous system
存储类别
6.1B - Non-combustible acute toxic Cat. 1 and 2 / very toxic hazardous materials
wgk
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter
A novel optoelectronic detector and improved flow analysis procedure for ammonia determination with Nessler?s reagent.
Kolacinska, Kamila, and Robert Koncki.
Analytical Sciences, 30.10, 1019-1022 (2014)
E.A. Burns et al.
The Analytical Chemistry of Nitrogen and its compounds, 51-51 (1970)
Santosh Kumar Verma et al.
Journal of AOAC International, 90(4), 1180-1190 (2007-09-01)
This paper presents development of a simple, rapid, and precise analytical method for determination of sulfur dioxide in ambient air by a gas to solid-phase conversion method. Sulfur dioxide is determined in the form of sulfite (SO3(2-)) because the absorbing
S J Lambert et al.
Acta crystallographica. Section D, Biological crystallography, 55(Pt 5), 1048-1051 (1999-04-27)
Intact histone octamers, produced by a new method quickly and in bulk, were crystallized in KCl/phosphate, and the X-ray data were analysed to 2.15 A, confirming a P65 space group. This environment preserves the high-resolution structure of the octamers and
Justyna Bzura et al.
Enzyme and microbial technology, 123, 1-7 (2019-01-29)
Two fully mechanized flow analysis systems for urease activity assays have been developed, characterized and compared. Both of them are based on almost the same compact system of solenoid micropumps and microvalves controlled and actuated by highly effective, low-power and
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持