eluent additive for LC-MS
suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for DIN 38407-42
suitable for EPA 1633
suitable for EPA 533
suitable for EPA 537.1
suitable for EPA 8327
suitable for EPA ACB B21-02
suitable for EPA ACB B23-05b
suitable for GB 31604.35-2016
suitable for GB 5009.253-2016
suitable for ISO 21675 2019
suitable for ISO 25101
suitable for ISO/CEN 15968-2010
suitable for FDA C-010.02
≥99.0% (calc. on dry substance, T)
solid
LiChropur™
LC/MS: suitable
insoluble matter, passes filter test
≤1% water
≤0.01% (as SO4)
6.2-7.5 (25 °C, 1 M in H2O)
110-112 °C (dec.) (lit.)
H2O: 1 M at 20 °C, clear, colorless
chloride (Cl-): ≤5 mg/kg
nitrate (NO3-): ≤10 mg/kg
sulfate (SO42-): ≤10 mg/kg
Al: ≤1 mg/kg
As: ≤0.1 mg/kg
Ba: ≤1 mg/kg
Bi: ≤1 mg/kg
Ca: ≤5 mg/kg
Cd: ≤1 mg/kg
Co: ≤1 mg/kg
Cr: ≤1 mg/kg
Cu: ≤1 mg/kg
Fe: ≤1 mg/kg
K: ≤5 mg/kg
Li: ≤1 mg/kg
Mg: ≤1 mg/kg
Mn: ≤1 mg/kg
Mo: ≤1 mg/kg
Na: ≤5 mg/kg
Ni: ≤1 mg/kg
Pb: ≤1 mg/kg
Sr: ≤1 mg/kg
Zn: ≤1 mg/kg
N.CC(O)=O
1 M in H2O
λ: 260 nm Amax: ≤0.015
λ: 280 nm Amax: ≤0.010
passes test for LC-MS
1S/C2H4O2.H3N/c1-2(3)4;/h1H3,(H,3,4);1H3
USFZMSVCRYTOJT-UHFFFAOYSA-N
正在寻找类似产品? Visit 产品对比指南
11 - Combustible Solids
WGK 1
Not applicable
Not applicable
Eyeshields, Gloves, type N95 (US)
输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。
为方便起见,与您过往购买产品相关的文件已保存在文档库中。
如何查找产品货号
在网站页面上,产品编号会附带包装尺寸/数量一起显示(例如:T1503-25G)。请确保 在“产品编号”字段中仅输入产品编号 (示例: T1503).
示例
其它示例:
705578-5MG-PW
PL860-CGA/SHF-1EA
MMYOMAG-74K-13
1000309185
输入内容 1.000309185)
遇到问题?欢迎随时联系我们技术服务 寻求帮助
如何查找COA批号
批号可以在产品标签上"批“ (Lot或Batch)字后面找到。
如果您查询到的批号为 TO09019TO 等,请输入去除前两位字母的批号:09019TO。
如果您查询到的批号含有填充代码(例如05427ES-021),请输入去除填充代码-021的批号:05427ES。
如果您查询到的批号含有填充代码(例如 STBB0728K9),请输入去除填充代码K9的批号:STBB0728。
部分情况下,可能未在线提供COA。如果搜索不到COA,可在线索取。
This study demonstrates the impact of various mobile phase modifiers on the separation; formate modifiers outperform acetate in terms of MS signals (or sensitivity) and chromatographic resolution.
Learn about the separation of several charge variants of two monoclonal antibodies, NISTmAb and Infliximab, using a polymeric cation exchange column and MS-compatible mobile phases.
Separation of null
Separation of Oxazepam; Desmethyldiazepam, analytical standard; Temazepam, analytical standard; Diazepam
Separation of Sorbitol; Mannitol
Protocol for HPLC Analysis of Dopamine and Related Compounds on Discovery® HS
HPLC Analysis of PEG on Two Zenix® SEC-300 Columns in Tandem
Strat-M® synthetic membrane mimics the human skin for In-vitro permeation testing (IVPT) of topical and transdermal formulations
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门