vapor density
3.9 (vs air)
Quality Level
vapor pressure
97.5 mmHg ( 20 °C)
product line
LiChropur™
assay
≥99.0% (GC)
form
liquid
technique(s)
LC/MS: suitable
impurities
≤0.05% water, ≤50 mg/kg total sulfur (as SO4)
refractive index
n20/D 1.3 (lit.)
bp
72.4 °C (lit.)
mp
−15.4 °C (lit.)
solubility
water: soluble 10,000 g/L
density
1.489 g/mL at 20 °C (lit.)
anion traces
chloride (Cl-): ≤50 mg/kg, sulfite (SO32-): ≤10 mg/kg
cation traces
Ag: ≤0.05 mg/kg, Al: ≤0.1 mg/kg, Ba: ≤0.1 mg/kg, Bi: ≤0.5 mg/kg, Ca: ≤0.5 mg/kg, Cd: ≤0.1 mg/kg, Co: ≤0.05 mg/kg, Cr: ≤0.1 mg/kg, Cu: ≤0.05 mg/kg, Fe: ≤1.0 mg/kg, K: ≤1.0 mg/kg, Li: ≤0.1 mg/kg, Mg: ≤1.0 mg/kg, Mn: ≤0.1 mg/kg, Mo: ≤0.05 mg/kg, NH4+: ≤10 mg/kg, Na: ≤1.0 mg/kg, Ni: ≤0.1 mg/kg, Pb: ≤0.05 mg/kg, Sr: ≤0.05 mg/kg, Tl: ≤0.1 mg/kg, Zn: ≤0.1 mg/kg
SMILES string
OC(C(F)(F)F)=O
UV absorption
λ: 260 nm Amax: ≤0.9, λ: 270 nm Amax: ≤0.1, λ: 280 nm Amax: ≤0.08, λ: 290 nm Amax: ≤0.07, λ: 300 nm Amax: ≤0.06, λ: 320 nm Amax: ≤0.05
suitability
passes test for LC-MS
InChI
1S/C2HF3O2/c3-2(4,5)1(6)7/h(H,6,7)
InChI key
DTQVDTLACAAQTR-UHFFFAOYSA-N
General description
特点:
- 全面的质量控制测试确保最高规格。
- 经过优化以提高电离和分辨率。
- 无机和有机杂质含量极低。
- 为精确、快速的LC-MS专门制造。
Application
Packaging
Legal Information
Still not finding the right product?
Explore all of our products under 三氟乙酸
signalword
Danger
hcodes
Hazard Classifications
Acute Tox. 4 Inhalation - Aquatic Chronic 3 - Eye Dam. 1 - Skin Corr. 1A
存储类别
8B - Non-combustible corrosive hazardous materials
wgk
WGK 2
法规信息
此项目有
实验方案
A complete workflow for the intact and middle-up mass analysis of reduced and non-reduced monoclonal antibodies based on SEC-MS with sample preparation by protein-A affinity clean-up.
SEC-MS protocol for rapid glycoprofiling of monoclonal antibodies with antibody purification and mass spectrometer calibration.
Aripiprazole, an atypical antipsychotic, treats schizophrenia, bipolar disorder, and major depressive disorder.
商品
The article describes the use of difluoroacetic acid (DFA) as an effective alternative to acid modifiers, formic acid (FA) and trifluoroacetic acid (TFA) in the LC-UV/MS analysis of proteins.
Compare columns in resolving medium-sized antibody fragments after digestion with DTT or IdeS using Reversed-Phase Chromatography for analysis.
Learn the tips and tricks of selecting and preparing a suitable mobile phase buffer for your HPLC separations and method developments for samples that contain ionizable compounds.
相关内容
ZipTip® micro-SPE pipette tips are used as a single-step desalting, concentration, and purification tool for complex samples before mass spec analyses.
全球贸易项目编号
| 货号 | GTIN |
|---|---|
| 80457-50ML-B | 04065269350439 |
| 80457-10X1ML | 04065269358695 |
| 80457-1ML-KC | 04065269350422 |
| 80457-10ML | 04065269358688 |