grade
analytical standard
Quality Level
assay
≥97.0% (HPLC)
optical activity
[α]1.15/D -0.5±0.5° in chloroform
shelf life
limited shelf life, expiry date on the label
drug control
USDEA Schedule IIIN; regulated under CDSA - not available from Sigma-Aldrich Canada
technique(s)
HPLC: suitable, gas chromatography (GC): suitable
application(s)
clinical testing
format
neat
functional group
ketone
storage temp.
2-8°C
SMILES string
C[C@]1(O)CC[C@H]2[C@@H]3CCC4=CC(=O)C=C[C@]4(C)[C@H]3CC[C@]12C
InChI
1S/C20H28O2/c1-18-9-6-14(21)12-13(18)4-5-15-16(18)7-10-19(2)17(15)8-11-20(19,3)22/h6,9,12,15-17,22H,4-5,7-8,10-11H2,1-3H3/t15-,16+,17+,18+,19+,20+/m1/s1
InChI key
XWALNWXLMVGSFR-HLXURNFRSA-N
Gene Information
human ... AR(367)
General description
17β-hydroxy-17-methylandrosta-1,4-dien-3-one is an androgenic anabolic steroid.
Application
17β-hydroxy-17-methylandrosta-1,4-dien-3-one may be used as a reference standard in the determination of 17β-hydroxy-17-methylandrosta-1,4-dien-3-one in urine samples, using by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS).
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.
Packaging
Bottomless glass bottle. Contents are inside inserted fused cone.
Still not finding the right product?
Explore all of our products under 17b-羟基-17a-甲基-1,4-雄甾二烯-3-酮
存储类别
11 - Combustible Solids
wgk
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
法规信息
监管及禁止进口产品
此项目有
Comparative study of matrices for their use in the rapid screening of anabolic steroids by matrix?assisted laser desorption/ionisation time?of?flight mass spectrometry
Galesio.M, et al.
Rapid Communications in Mass Spectrometry, 23, 1783-1791 (2009)
Stephanie Mosler et al.
Archives of toxicology, 86(1), 109-119 (2011-08-06)
There is increasing evidence that the biological activity of myostatin (MSTN), a negative regulator of muscle growth, is affected by training but also anabolic steroids. In this study, we analyzed the effects of the frequently abused anabolic steroid methandienone (Md)
Oscar J Pozo et al.
Drug testing and analysis, 1(11-12), 554-567 (2010-04-01)
Anabolic steroids are among the most frequently detected compounds in doping analysis. They are extensively metabolized and therefore an in-depth knowledge about steroid metabolism is needed. In this study, a liquid chromatography tandem mass spectometry (LC-MS/MS) method based on a
全球贸易项目编号
| 货号 | GTIN |
|---|---|
| 90151-100MG | 04061833246429 |