所有图片(3)
About This Item
线性分子式:
CaSO4 · 2H2O
CAS号:
分子量:
172.17
EC 号:
MDL编号:
UNSPSC代码:
12352300
PubChem化学物质编号:
NACRES:
NA.55
方案:
≥99%
表单:
powder
推荐产品
质量水平
产品线
ReagentPlus®
方案
≥99%
表单
powder
SMILES字符串
O.O.[Ca++].[O-]S([O-])(=O)=O
InChI
1S/Ca.H2O4S.2H2O/c;1-5(2,3)4;;/h;(H2,1,2,3,4);2*1H2/q+2;;;/p-2
InChI key
PASHVRUKOFIRIK-UHFFFAOYSA-L
正在寻找类似产品? 访问 产品对比指南
应用
二水合硫酸钙可作为开环聚合取代环三磷腈的促进剂。
法律信息
ReagentPlus is a registered trademark of Merck KGaA, Darmstadt, Germany
储存分类代码
11 - Combustible Solids
WGK
WGK 1
闪点(°F)
Not applicable
闪点(°C)
Not applicable
历史批次信息供参考:
分析证书(COA)
Lot/Batch Number
Structural characterizations, thermal behavior, and electrical measurements of the amidosulfonic acid catalyzed thermal ring-opening polymerization of substituted cyclotriphosphazene in 1, 2, 4-trichlorobenzene solution
Koran K, et al.
Advances in Polymer Technology, 37, 3229-3239 (2018)
Ji Liu et al.
Nature communications, 11(1), 1071-1071 (2020-02-28)
The adhesion of soft connective tissues (tendons, ligaments, and cartilages) on bones in many animals can maintain high toughness (∽800 J m-2) over millions of cycles of mechanical loads. Such fatigue-resistant adhesion has not been achieved between synthetic hydrogels and engineering materials
Eun Young Rha et al.
Plastic and reconstructive surgery, 133(1), 14-20 (2014-01-01)
The authors have developed a simple and intuitive method for measuring breast volume based on three-dimensional simulated images of magnetic resonance imaging scans to accurately estimate breast volume before breast reconstruction. The authors performed a retrospective review of the medical
Sung-Yen Lin et al.
The Journal of hand surgery, 38(1), 104-109 (2012-12-04)
Enchondroma of the hand with a pathologic fracture is generally treated by tumor curettage and bone grafting after the fracture has healed. However, delayed surgery postpones definitive diagnosis and prolongs the period of disability. We have treated pathologic fractures in
Aletta Hazeveld et al.
American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics, 145(1), 108-115 (2014-01-01)
Rapid prototyping is a fast-developing technique that might play a significant role in the eventual replacement of plaster dental models. The aim of this study was to investigate the accuracy and reproducibility of physical dental models reconstructed from digital data
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门