跳转至内容
Merck
CN

C3771

硫酸钙 二水合物

ReagentPlus®, ≥99%

别名:

二水石膏

登录 查看公司和协议定价

选择尺寸


关于此项目

线性分子式:
CaSO4 · 2H2O
化学文摘社编号:
分子量:
172.17
EC 号:
MDL编号:
UNSPSC代码:
12352300
PubChem化学物质编号:
NACRES:
NA.55
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助

产品线

ReagentPlus®

方案

≥99%

表单

powder

SMILES字符串

O.O.[Ca++].[O-]S([O-])(=O)=O

InChI

1S/Ca.H2O4S.2H2O/c;1-5(2,3)4;;/h;(H2,1,2,3,4);2*1H2/q+2;;;/p-2

InChI key

PASHVRUKOFIRIK-UHFFFAOYSA-L

正在寻找类似产品? 访问 产品对比指南

应用

二水合硫酸钙可作为开环聚合取代环三磷腈的促进剂

法律信息

ReagentPlus is a registered trademark of Merck KGaA, Darmstadt, Germany

储存分类代码

11 - Combustible Solids

WGK

WGK 1

闪点(°F)

Not applicable

闪点(°C)

Not applicable


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Structural characterizations, thermal behavior, and electrical measurements of the amidosulfonic acid catalyzed thermal ring-opening polymerization of substituted cyclotriphosphazene in 1, 2, 4-trichlorobenzene solution
Koran K, et al.
Advances in Polymer Technology, 37, 3229-3239 (2018)
Kathryn A Dooley et al.
The Analyst, 138(17), 4838-4848 (2013-06-27)
In situ chemical imaging techniques are being developed to provide information on the spatial distribution of artists' pigments used in polychrome works of art such as paintings. The new methods include reflectance imaging spectroscopy and X-ray fluorescence mapping. Results from
Massimo Peruffo et al.
Physical chemistry chemical physics : PCCP, 15(6), 1956-1965 (2012-12-22)
Dissolution processes at single crystal surfaces often involve the initial formation and expansion of localized, characteristic (faceted) etch-pits at defects, in an otherwise comparatively unreactive surface. Using natural gypsum single crystal as an example, a simple but powerful morphological analysis
Joon Im et al.
American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics, 145(4), 434-442 (2014-04-08)
The aim of this study was to compare the virtual and manual tooth setups with digital and plaster models in extraction cases by measuring various occlusal parameters and applying the American Board of Orthodontics objective grading system. Linear intra-arch and
Ji Liu et al.
Nature communications, 11(1), 1071-1071 (2020-02-28)
The adhesion of soft connective tissues (tendons, ligaments, and cartilages) on bones in many animals can maintain high toughness (∽800 J m-2) over millions of cycles of mechanical loads. Such fatigue-resistant adhesion has not been achieved between synthetic hydrogels and engineering materials

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.