跳转至内容
Merck
CN

41367

Anti-Rabbit IgG−Abberior® STAR 580 antibody produced in goat

别名:

Abberior® STAR 580-Anti-Rabbit IgG antibody produced in goat

登录 查看组织和合同定价。

选择尺寸

变更视图

关于此项目

NACRES:
NA.45
UNSPSC Code:
12352200
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


biological source

goat

Quality Level

antibody form

affinity isolated antibody

antibody product type

secondary antibodies

clone

polyclonal

form

buffered aqueous solution

species reactivity

rabbit

concentration

~1 mg/mL

fluorescence

λex 587 nm; λem 607 nm in PBS, pH 7.4

storage temp.

−20°C

General description

Abberior STAR 580 was developed for STED and confocal microscopy in the orange spectral region. Abberior STAR 580 is highly photostable and bright orange fluorescent dye. The dye works extremely well with Abberior Instruments STEDYCON and Expert Line Microscopes and Leica STED microscopes. It can be very effectively excited with excitation wavelength between 550 - 600 nm. Abberior STAR 580 can substitute dyes like Cy3, Atto 590 or Alexa Fluor 568. For STED microscopy, Abberior STAR 580 can be used most efficiently with a STED Laser wavelength between 750 - 800 nm. Abberior STAR 580 is the ideal partner for Abberior STAR RED or Abberior STAR 635P to obtain optimal 2 Color STED results. Best results are obtained with freshly prepared samples.


Photophysical properties (carboxylic acid):
Absorption Maximum, λex [nm]: 587 (PBS pH 7.4), 584 (H2O), 584 (MeOH)
Extinction Coefficient, εmax [M-1cm-1]: 85 000 (PBS pH 7.4), 85 000 (H2O), 95 000 (MeOH)
Correction Factor, CF260 = ε260max: 0,17 (PBS pH 7.4)
Correction Factor, CF280 = ε280max: 0,17 (PBS pH 7.4)
Fluorescence Maximum, λem [nm]: 607 (PBS pH 7.4), 607 (H2O), 604 (MeOH)
Recommended STED Wavelength, λ [nm]: 750-800
Fluorescence Quantum Yield, λ: 0,90 (PBS pH 7.4)
Fluorescence Lifetime, τ [ns]: 3,5 (PBS pH 7.4)

Application

Designed and tested for fluorescent super-resolution microscopy

Analysis Note

May contain significant amounts of BSA as stabilizer
unconjugated dye ≤5% of total fluorescence

Legal Information

ALEXA FLUOR is a trademark of Life Technologies
Atto is a trademark of Atto-Tec GmbH
Cy3 is a trademark of Cytiva
abberior is a registered trademark of Abberior GmbH


Still not finding the right product?

试用我们的 产品选型工具 工具缩小选择范围


存储类别

12 - Non Combustible Liquids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

法规信息

新产品

此项目有



历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库



Eulashini Chuntharpursat-Bon et al.
Communications biology, 6(1), 358-358 (2023-04-04)
Two prominent concepts for the sensing of shear stress by endothelium are the PIEZO1 channel as a mediator of mechanically activated calcium ion entry and the PECAM1 cell adhesion molecule as the apex of a triad with CDH5 and VGFR2.
Francisco Balzarotti et al.
ACS nano, 6(6), 4580-4584 (2012-06-19)
Plasmonics and near-field optical nanoscopy both deal with expanding optics into the subwavelength regime. However, these two fields have so far followed parallel paths of development and only recently have researchers started to explore combinations of their concepts with potential
Esley Torres-García et al.
Nature communications, 13(1), 7452-7452 (2022-12-03)
The resolution of fluorescence microscopy images is limited by the physical properties of light. In the last decade, numerous super-resolution microscopy (SRM) approaches have been proposed to deal with such hindrance. Here we present Mean-Shift Super Resolution (MSSR), a new