A0156
N-(4-氨基丁基)-N-乙基异鲁米诺
≥90%, powder
别名:
4-(N1-乙基-4-氨基丁基氨基)邻苯二甲酰肼, 6-[N-(4-氨基丁基)-N-乙氨基]-2,3-二氢-1,4-邻苯二甲酰肼, ABEI
登录查看公司和协议定价
选择尺寸
关于此项目
经验公式(希尔记法):
C14H20N4O2
化学文摘社编号:
分子量:
276.33
Beilstein:
920895
MDL编号:
UNSPSC代码:
12352204
PubChem化学物质编号:
NACRES:
NA.83
产品名称
N-(4-氨基丁基)-N-乙基异鲁米诺, ≥90%
质量水平
方案
≥90%
表单
powder
mp
259-260 °C (lit.)
溶解性
glacial acetic acid: 50 mg/mL, clear, colorless to yellow
储存温度
2-8°C
SMILES字符串
CCN(CCCCN)c1ccc2C(=O)NNC(=O)c2c1
InChI
1S/C14H20N4O2/c1-2-18(8-4-3-7-15)10-5-6-11-12(9-10)14(20)17-16-13(11)19/h5-6,9H,2-4,7-8,15H2,1H3,(H,16,19)(H,17,20)
InChI key
LEOJISUPFSWNMA-UHFFFAOYSA-N
正在寻找类似产品? 访问 产品对比指南
特点和优势
高效的化学发光 NH2 偶联试剂,用于检测低至皮摩尔范围的各种蛋白质。
其他说明
据报道,在化学发光测定中使用这种材料具有明显优于传统放射免疫测定的优点。
储存分类代码
11 - Combustible Solids
WGK
WGK 3
闪点(°F)
Not applicable
闪点(°C)
Not applicable
个人防护装备
Eyeshields, Gloves, type N95 (US)
历史批次信息供参考:
分析证书(COA)
Lot/Batch Number
Minli Yang et al.
The Analyst, 127(9), 1267-1271 (2002-10-12)
The electrogenerated chemiluminescence (ECL) behavior of N-(4-aminobutyl)-N-ethylisoluminol (ABEI) was studied and it was found that ABEI could produce emission light when oxidized at a +1.0 V (vs. Ag/AgCl) potential in alkaline solution. The addition of H2O2 markedly improved the ECL
Jialing Chen et al.
Clinica chimica acta; international journal of clinical chemistry, 488, 143-149 (2018-11-11)
Lipoprotein-associated phospholipase A2 (Lp-PLA2) is a novel inflammatory biomarker, which is useful as an adjunct identification tool for cardiovascular disease. However, the important limitation of the conventional enzyme-linked immunosorbent assay (PLAC ELISA) for Lp-PLA2 assay is its relatively low sensitivity
C J Strasburger et al.
Journal of bioluminescence and chemiluminescence, 4(1), 112-118 (1989-07-01)
The tetrameric structure of streptavidin and its exceptionally strong affinity to biotin (Ka = 10(15)M 1) can be exploited to achieve an amplification of the signal in immunoassays. In the approach described here streptavidin (STAV) labelled with aminobutylethyl-isoluminol (ABEI) served
M-L Calvo-Muñoz et al.
Bioelectrochemistry (Amsterdam, Netherlands), 66(1-2), 139-143 (2005-04-19)
The electrochemiluminescence (ECL) of a luminol derivate (ABEI) generated both by a carbon electrode and a polypyrrole-coated carbon electrode was examined. It was found that the polypyrrole film (ppy) did not inhibit the ECL. After that, ABEI anchored on a
Ying Chai et al.
Analytica chimica acta, 715, 86-92 (2012-01-17)
An electrochemiluminescence (ECL) biosensor for simultaneous detection of adenosine and thrombin in one sample based on bifunctional aptamer and N-(aminobutyl)-N-(ethylisoluminol) functionalized gold nanoparticles (ABEI-AuNPs) was developed. A streptavidin coated gold nanoparticles modified electrode was utilized to immobilize biotinylated bifunctional aptamer
我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系客户支持