biological source
rabbit skin
Quality Level
description
acid soluble
form
powder
technique(s)
cell culture | stem cell: suitable
solubility
aqueous acid: ≤10 mg/mL, aqueous sodium acetate buffer: soluble (0.01-0.5M)
UniProt accession no.
storage temp.
2-8°C
Gene Information
rabbit ... COL1A2(100008997)
General description
Collagen is classified into a number of structurally and genetically distinct types. We use the nomenclature proposed by Bornstein and Traub. Do not confuse Sigma type designations with recognized collagen classification types.
Application
Collagen-type 1 may be used in research of Idiopathic pulmonary fibrosis (IPF). Robust expression of collagen-type 1 is one distinctive feature of IPF. Additionally, collagen-type 1 has been used in studies on the effect of endoplasmic reticulum (ER) stress from IPF on myofibroblastic differentiation of lung fibroblasts. Collage-type 1 soluble in acidic solution produces three dimensional scaffolding useful in bioengineering and cell culture applications where biomaterials are needed to replace native collagen extracellular matrices.
Collagen Type I has been used as a scaffold for the growth in vitro of stem cells in a wide variety of biomaterial engineering studies.
Collagen Type I has been used as a scaffold for the growth in vitro of stem cells in a wide variety of biomaterial engineering studies.
Preparation Note
Prepared with modification of Gallop, P.M.
存储类别
11 - Combustible Solids
wgk
WGK 1
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Gloves, type N95 (US)
法规信息
新产品
此项目有
Prasad L Polavarapu et al.
Chirality, 23(9), 801-807 (2011-12-03)
Fourier transform infrared vibrational circular dichroism (FTIR-VCD) measurements have gone through major advances in the last decade. A major thrust in these advances was to find ways that can minimize the VCD spectral artifacts and obtain the VCD signals at
Simon Holland et al.
Current opinion in ophthalmology, 24(4), 302-309 (2013-05-18)
Topography-guided laser refractive surgery regularizes the front corneal surface irregularities to achieve the desired refractive outcome. This is particularly applicable in highly aberrated corneas, where wavefront aberrometry is often not possible. This article aims to review the recently published results
Marco Esposito et al.
European journal of oral implantology, 6(2), 169-179 (2013-08-09)
To compare the clinical effectiveness of two implant systems: Way Milano and Kentron (Geass, Pozzuolo del Friuli, UD, Italy). A total of 64 patients requiring at least two single crowns or partial fixed dental prostheses supported by a maximum of
全球贸易项目编号
| 货号 | GTIN |
|---|---|
| C5608-100MG | 04061833270004 |