跳转至内容
Merck
CN

GE17-0402-01

HiTrap® Protein A High Performance

Cytiva 17-0402-01, pack of 5 × 1 mL

别名:

Protein A Affinity Column

登录并加购,请在购物车里查看协议价、货期和发货地。

选择规格

变更视图

关于此项目

NACRES:
NA.56
UNSPSC Code:
23151816
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


form

prepacked column

crosslinking

cross-linked

packaging

pack of 5 × 1 mL

manufacturer/tradename

Cytiva 17-0402-01

storage condition

(20% Ethanol)

parameter

0.5 Mpa max. pressure, 1 mL/min flow rate, 4 mL/min max. flow rate

technique(s)

liquid chromatography (LC): suitable

bed volume

1 mL

column I.D. × L

7 mm × 25 mm

matrix

highly cross-linked agarose, spherical

matrix active group

Protein A

avg. part. size

34 μm

cleaning

2-10

working range

3-9

capacity

~20 mg binding capacity (human IgG / mL resin)

separation technique

affinity

storage temp.

2-8°C

General description

HiTrap® Protein A HP is a prepacked Protein A Sepharose™ High Performance column for preparative purification of monoclonal and polyclonal antibodies from ascites, serum, and cell culture supernatants.

HiTrap® Protein A HP is a prepacked ready to use, column for preparative purification of monoclonal and polyclonal antibodies. The special design of the column, together with the medium provide fast, simple and easy separations in a convenient format.
pH below 3 is sometimes required to elute strongly bound IgG species. However, protein ligands may hydrolyze at very low pH.

Features and Benefits

  • High binding capacitiy of 20 mg IgG/mL medium and fast kinetics.
  • 34 μm bead size for high-performance, high-resolution purifications.
  • Designed for use with syringe, pump, or chromatography system such as AKTA design or FPLC™ System.
  • Stable over pH 3 to 9 for use, and 2 to 10 for cleaning.
  • Robust, easy-to-use method.

Preparation Note

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

Analysis Note

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Other Notes

The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.

Legal Information

FPLC is a trademark of Cytiva
HiTrap is a registered trademark of Cytiva
Sepharose is a trademark of Cytiva


Still not finding the right product?


象形图

Flame

警示词

Warning

危险代码

存储类别

3 - Flammable liquids



历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库