跳转至内容
Merck
CN

SML1074

R1530

≥98% (HPLC)

别名:

5-(2-Chlorophenyl)-7-fluoro-1,2-dihydro-8-methoxy-3-methyl-pyrazolo[3,4-b][1,4]benzodiazepine

登录 查看组织和合同定价。

选择尺寸

变更视图

关于此项目

经验公式(希尔记法):
C18H14ClFN4O
化学文摘社编号:
分子量:
356.78
UNSPSC Code:
12352200
PubChem Substance ID:
MDL number:
Assay:
≥98% (HPLC)
Form:
powder
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


assay

≥98% (HPLC)

form

powder

drug control

regulated under CDSA - not available from Sigma-Aldrich Canada

color

, white to yellow to light brown

solubility

DMSO: 20 mg/mL, clear

storage temp.

2-8°C

SMILES string

ClC1=CC=CC=C1C2=NC3=C(C)NN=C3NC4=C2C=C(F)C(OC)=C4

InChI

1S/C18H14ClFN4O/c1-9-16-18(24-23-9)21-14-8-15(25-2)13(20)7-11(14)17(22-16)10-5-3-4-6-12(10)19/h3-8H,1-2H3,(H2,21,23,24)

InChI key

UOVCGJXDGOGOCZ-UHFFFAOYSA-N

Biochem/physiol Actions

R1530 is a multi-kinase inhibitor and an anti tumor agent.
R1530 is a multi-kinase inhibitor with activity against several kinases associated with tumor growth and angiogenesis, including VEGFR, FGFR, PDGFR, Chk2 and Cdk2. In tumor cells, R1530 inhibits tubulin polyerization and mitotic checkpoint function, resulting in polyploidy. The compound R1530 inhibits tumor growth and angiogenesis in animal models.


pictograms

Exclamation mark

signalword

Warning

Hazard Classifications

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

target_organs

Respiratory system

存储类别

11 - Combustible Solids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

法规信息

新产品

此项目有



历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库



Amreena Suri et al.
International journal of molecular sciences, 20(9) (2019-05-01)
Polo-like kinase 4 (PLK4) is a cell cycle-regulated protein kinase (PK) recruited at the centrosome in dividing cells. Its overexpression triggers centrosome amplification, which is associated with genetic instability and carcinogenesis. In previous work, we established that PLK4 is overexpressed
Tomas Vanek et al.
Journal of environmental science and health. Part A, Toxic/hazardous substances & environmental engineering, 50(11), 1148-1159 (2015-07-21)
Performance of a two-stage biofiltration system was investigated for removal of styrene-acetone mixtures. High steady-state acetone loadings (above C(in)(Ac) = 0.5 g.m(-3) corresponding to the loadings > 34.5 g.m(-3).h(-1)) resulted in a significant inhibition of the system's performance in both



全球贸易项目编号

货号GTIN
SML1074-25MG04061832963396
SML1074-5MG04061832963402